26
• Items that are turned off using the <DISPLAY> page
settings of the VIDEO/MONITOR menu are not displayed.
• A “-” mark is displayed for each item when a camera is not
connected.
System status
CHU Mode:
CHU MODE (connected camera) setting
Reference:
Reference signal format used and genlock status
(“Not detected” is displayed when a reference signal is not
input.)
Slot1:
Output signal format of SLOT1
Slot2:
Output signal format of each connector of SLOT2
Slot3:
Output signal format of each connector of SLOT3
Camera system diagnostics
Optical Condition CAM:
Camera light sensor level
Optical Condition CCU:
Unit light sensor level
Camera Cable:
Camera cable connection status
Power Supply:
Camera power supply status
Cable Length:
Cable length
Network Link Status:
LAN connection status
CCU No.:
CCU number setting status
Camera and unit audio status
Camera MIC Gain CH1:
Camera microphone circuit 1 amp
gain status
Camera MIC Gain CH2:
Camera microphone circuit 2 amp
gain status
CCU Audio Out:
Output format of the AUDIO OUT connector
of the unit
Camera and unit intercom status
Camera Engineer:
Camera microphone status of the ENG
line of the camera
Camera Producer:
Camera microphone status of the PROD
line of the camera
CCU MIC/PGM:
Status of MIC/PGM switch on the front of the
unit
CCU Line:
Intercom system connection status
Notes
*System Status* 01/05
CHU Mode :HDC4300
Reference:1080/59.94I Locked
Slot1 :1080/59.94P(3x)/3G-B
Slot2-1 :1080/59.94P/3G-A
2-2 :1080/59.94P/3G-B
2-3 :1080/59.94P/Link-A
2-4 :1080/59.94P/Link-B
Slot3-1 1080/59.94I
3-2 525/59.94I
*System Diagnosis* 02/05
Optical Condition
CAM
ss
xxx
xxxg
OK
CCU
ss
xxx
xxxg
Warning
Camera Cable :Connected
Power Supply :OK
Cable Length :
100m
Network
Link Status :Up
CCU No. :10
*Audio* 03/05
Camera
MIC Gain CH1 :60dB
CH2 :60dB
CCU
Audio Out :AES/EBU
*Intercom* 04/05
Camera
Engineer :MIC On
Producer :MIC Off
CCU
MIC/PGM :MIC Off