SELF-DIAGNOSIS FUNCTION
The self-diagnosis function consists of error codes for users which are displayed automatically when errors occur, and error codes which
show the error history in the test mode during servicing. For details on how to view error codes for users, refer to the following box in the
instruction manual. For details on how to perform checks during servicing, refer to the following “Procedure for Using the Self-Diagnosis
Function (Error History Display Mode)”.
Procedure for Using the Self-Diagnosis Function (Error History Display Mode)
Note:
Perform the self-diagnosis function in the “error history display mode” in the test mode. The following describes the least required
steps. Be careful not to enter other modes by mistake. If other modes are set accidentally, press the
^
(CD) button to exit that
mode.
1. With the power off, press the
^
(MD) button while pressing the PLAY MODE button.
2. Rotate the VOLUME knob until “ERR DP MODE” is displayed.
3. Pressing the
p
(CD) button sets the error history mode and displays “total rec”.
4. Select the contents to be displayed or executed using the VOLUME knob.
5. Pressing the
6
(CD) button displays or executes the contents selected.
6. Pressing the
6
(CD) button another time returns to step 4.
7. Pressing the
^
(CD) button displays “ERR DP MODE” and exits the error history mode.
8. To exit the test mode, press the REPEAT button. The unit sets into the STANDBY state, and the test mode ends.
Содержание HCD-MD333 - Hi Fi Cd/minidisc Component
Страница 2: ... 2 ...
Страница 9: ... 9 This section is extracted from instruction manual ...
Страница 48: ...HCD MD333 65 66 7 16 SCHEMATIC DIAGRAM PANEL SECTION Page 55 Page 70 ...
Страница 50: ...HCD MD333 69 70 7 18 SCHEMATIC DIAGRAM JACK SECTION Page 61 Page 65 Page 55 Page 78 ...
Страница 54: ...HCD MD333 77 78 7 24 SCHEMATIC DIAGRAM POWER AMP SECTION Page 57 Page 70 Page 75 ...