– 25 –
6-6. LASER POWER ADJUSTMENT
Connection :
KMS
260A
27X40
B0825
N
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
6-7. TRAVERSE ADJUSTMENT
Connection :
Adjusting Procedure:
1. Connect an oscilloscope to TP (TEO) and TP (VC) of CN110 of
the BD (MD) board.
2. Load a recordable disc (any available on the market). (Refer to
Note 1.)
3. Press the
=
0
or
)
+
button to move the optical
pick-up outside the pit.
4. Rotate the VOLUME knob to display “EFBAL ADJUST”.
5. Press the
p
(CD) button to display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Rotate the VOLUME knob so that the oscilloscope waveform
becomes the specified value. (Rotating the VOLUME knob
changes the “EFB=
” value and the waveform.) The waveform
changes by about 2% everytime when adjusted. Adjust as close
as possible to the specified value.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the
p
(CD) button and save the adjustment results in the
non-volatile memory (displayed as “EFB =
SAVE”
momentarliy and then displayed as “EFB =
MO-W”).
8. Rotate the VOLUME knob so that the oscilloscope waveform
becomes the specified value.
(Rotating the VOLUME knob changes the “EFB=
” value
and the waveform.) The waveform changes by about 2%
everytime when adjusted. Adjust as close as possible to the
specified value.
(Write Power Traverse Adjustment)
(Traverse Waveform)
Laser power
meter
Optical pick-up
objective lens
Digital volt meter
TP (I+3V)
TP (IOP)
BD (MD) board
Adjusting Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up from the disc slot. (If it cannot be set properly, press the
=
0
or
)
+
button to move the optical pick-up).
Connect the digital voltmeter to TP (I+3V) and TP (IOP) of the
BD (MD) board.
2. Rotate the VOLUME knob to display “LDPWR ADJUST”.
(Laser power: For adjustment)
3. Press the
p
(CD) button once to display “LD 0.9 mW $
”.
4. Rotate the VOLUME knob so that the laser power meter reads
0.86 to 0.92 mW. Set the range knob of the laser power meter to
10 mW, press the
p
(CD) button, and save the adjustment results
in the non-volatile memory. (“LD SAVE $
” is displayed
momentarily.)
5. “LD 7.0 mW $
” is next displayed.
6. Rotate the VOLUME knob so that the laser power meter reads
6.9 to 7.1 mW, press the
p
(CD) button, and save the adjustment
results in the non-volatile memory. (“LD SAVE $
” is displayed
momentarily.)
Note: Do not emit 7.0 mW continuously for more than 15 seconds.
7. Rotate the VOLUME knob to display “LDPWR CHECK”.
8. Press the
p
(CD) button once to display “LD 0.9 mW $
”.
Check that the laser power meter reading is 0.85 to 0.91 mW.
9. Press the
p
(CD) button another time to diaplay “LD 7.0 mW
$
”.
Check that the readings of the laser power meter and digital
voltmeter become the specified value.
Specified Value :
Laser power meter reading : 7.0 ± 0.1 mW
Digital voltmeter reading : Value displayed on optical pick-up label
± 10%
(Optical pick-up label)
10. Press the
^
(CD) button to display “LDPWR CHECK” and
stop the laser emission.
(The
^
(CD) button is effective at all times to stop the laser
emission.)
VC
A
B
Specified value : A = B
VC
A
B
Specified value : A = B
9. Press the
p
(CD) button to save the adjustment results in the
non-volatile memory (displayed as “EFB =
SAVE”
momentarliy).
Oscilloscope
TP (TEO)
TP (VC)
BD (MD) board
Содержание HCD-MD333 - Hi Fi Cd/minidisc Component
Страница 2: ... 2 ...
Страница 9: ... 9 This section is extracted from instruction manual ...
Страница 48: ...HCD MD333 65 66 7 16 SCHEMATIC DIAGRAM PANEL SECTION Page 55 Page 70 ...
Страница 50: ...HCD MD333 69 70 7 18 SCHEMATIC DIAGRAM JACK SECTION Page 61 Page 65 Page 55 Page 78 ...
Страница 54: ...HCD MD333 77 78 7 24 SCHEMATIC DIAGRAM POWER AMP SECTION Page 57 Page 70 Page 75 ...