– 26 –
10. Next “EFB =
MO-P” is displaed, the optical pick-up moves
to the internal circumference of the pit and servo is imposed.
11. Rotate the VOLUME knob so that the oscilloscope waveform
becomes the specified value.
The waveform changes by about 2% everytime when adjusted.
Adjust as close as possible to the specified value.
(Traverse Waveform)
12. Press the
p
(CD) button and save the adjustment results in the
non-volatile memory (displayed as “EFB =
SAVE”
momentarliy).
“EFBAL: CD is next displayed and the disc stops rotating
automatically.
13. Press the
6
(MD) button and remove the disc.
14. Load the check disc (MD) TDYS-1.
15. Press the
p
(CD) button to display “EFB =
CD”. The servo
is imposed automatically.
16. Rotate the VOLUME knob so that the oscilloscope waveform
becomes the specified value.
The waveform changes by about 2% everytime when adjusted.
Adjust as close as possible to the specified value.
(Traverse Waveform)
17. Press the
p
(CD) button and save the adjustment results in the
non-volatile memory after “EFB =
SAVE” is momentarliy
displayed.
“EFBAL ADJUST” is next displayed.
18. Press the
6
(MD) button and remove the check disc (MD)
TDYS-1.
Note 1 : The data will be overwritten on the MO and erased when a
recorded disc is used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
VC
A
B
Specified value : A = B
VC
A
B
Specified value : A = B
330 k
Ω
Oscilloscope
10pF
BD (MD) board
TP (TEO)
TP (VC)
6-8. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load a continuously recorded disc (Refer to 6-4. Creating the
Continuously Recorded Disc”).
2. Rotate the VOLUME knob to display “CPLAY MODE”.
3. Press the
p
(CD) button to display “CPLAY MID”.
4. When “C1 =
AD =
” is displayed, press the
^
(CD)
button.
5. Rotate the VOLUME knob to display “FBIAS ADJUST”.
6. Press the
p
(CD) button to display “
/
a =
”.
The first four digits indicate the C1 error rate, the two digits
after the “/” indicate ADER and the two digits after “a =” indicate
the focus bias value.
7. Rotate the VOLUME knob in the clockwise direction, and look
for the focus bias value at which the C1 error rate becomes
approximately approx. 200. (Refer to Note 2).
8. Press the
p
(CD) button to display “
/
b =
”.
9. Rotate the VOLUME knob in the counterclockwise direction,
and look for the focus bias value at which the C1 error rate
becomes approx. 200.
Check that the C1 error rate becomes almost equal to the value
set in step 7.
10. Press the
p
(CD) button to display “
/
c =
”.
11. Check that the C1 error rate is below 50 and that ADER is 00.
and press the
p
(CD) button.
12. If the value of “(
)” in the “
-
-
(
)” displayed is
above 20, press the
p
(CD) button.
If below, press the
^
(CD) button and start from step 2 again.
13. Press the
6
button and remove the continuously recorded disc.
Note 1 : The following figure shows the relation between the C1
error and focus bias value. Look for points a and b in the
following figure by the adjustment avove. The focus
position (point c) is automatically calculated from points
a and b.
Note 2 : As the C1 error rate changes, use the average value in the
adjustment.
C1 error
approx.
200
b
c
a
Focus bias value
(F. BIAS)
Содержание HCD-MD333 - Hi Fi Cd/minidisc Component
Страница 2: ... 2 ...
Страница 9: ... 9 This section is extracted from instruction manual ...
Страница 48: ...HCD MD333 65 66 7 16 SCHEMATIC DIAGRAM PANEL SECTION Page 55 Page 70 ...
Страница 50: ...HCD MD333 69 70 7 18 SCHEMATIC DIAGRAM JACK SECTION Page 61 Page 65 Page 55 Page 78 ...
Страница 54: ...HCD MD333 77 78 7 24 SCHEMATIC DIAGRAM POWER AMP SECTION Page 57 Page 70 Page 75 ...