HCD-DJ2i
24
CD REPEAT 5 LIMIT OFF MODE
• The number of repeat for CD playback is 5 times when the
repeat mode is “REPEAT ALL”. This mode enables CD to
repeat playback for limitless times.
• Procedure:
1. Press
[
?/1
] button to turn the set ON.
2. Select CD function.
3. Press [CD] button, [BEAT LEVEL] button and
[MENU/RETURN] on CHANNEL A button
simultaneously to enter the CD repeat 5 limit off mode
and the fl uorescent indicator tube displays “LIMIT OFF”.
4. To release from this mode, operate the cold reset. (Refer
to the “MC COLD RESET”)
CD SHIP MODE (WITH MEMORY CLEAR)
• This mode moves the optical pick-up to the position durable
to vibration and clears all data including preset data stored in
the RAM to initial conditions. Use this mode when returning
the set to the customer after repair.
• Procedure:
1. Press
[
?/1
] button to turn the set ON.
2. Select CD function.
3. Press [CD] button, [BPM CONTROL] button and [
?/1
]
button simultaneously. The set will power off
automatically.
4. After the “STANDBY” blinking display fi nishes, a
message “MECHA LOCK” is displayed on the
fl uorescent indicator tube and the CD ship mode is set.
5. Then AC power OFF.
CD SHIP MODE (WITHOUT MEMORY CLEAR)
• This mode moves the optical pick-up to the position durable
to vibration. Use this mode when returning the set to the
customer after repair.
• Procedure:
1. Press
[
?/1
] button to turn the set ON.
2. Select CD function.
3. Press [CD] button and [
?/1
] button simultaneously. The
set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a
message “MECHA LOCK” is displayed on the
fl uorescent indicator tube and the CD ship mode is set.
5. The AC power OFF.
CD TRAY LOCK MODE
• This mode let you lock the disc tray. When this mode is
activated, the disc tray will not open when [
A
] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube.
• Procedure:
1. Press
[
?/1
] button to turn the set ON.
2. Select CD function.
3. Press
[
s
] button and [
A
] button simultaneously and hold
down until “LOCKED” or “UNLOCKED” displayed on
the fl uorescent indicator tube (around 5 seconds).
VACS DISPLAY
• This mode is used to check the VACS level.
• Procedure:
1. Press
[
?/1
] button to turn on the system.
2. Press
[
s
] button, [PAD I] button and [OPTIONS] button
simultaneously.
3. The VACS Level Display, the fl uorescent indicator tube
displays “VACS X”. It represents VACS level which is
triggered by signal level.
4. To release from this mode, press [
s
] button, [PAD I]
button and [OPTIONS] button simultaneously again.