3-3. SERVO SYSTEM ADJUSTMENTS
1. CAP FG Offset Adjustment (VC-214 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
Pin
!™
of CN910 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
61
Specified value
Duty = 50 ± 1 %
Adjusting method:
1)
Set to the Camera recording mode (SP mode).
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 01, set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
4)
Select page: 6, address: 02, and check that the data is “01”.
5)
Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 6, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 1) to 5).
6)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
2. Switching Position Adjustment (VC-214 board)
If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment
(WR5-1CP)
Measurement Point
CH1: Pin
!¡
of CN910 (RF SWP)
CH2: Pin
6
of CN910 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
3E, 3F
Specified Value
t1 = 0 ± 10
µ
sec
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 2C, set data: 20, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 3E, change the data and minimize “t1”,
and then press the PAUSE button of the adjustment remote
commander. (Coarse adjustment)
4)
Select page: F, address: 3F, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
A
B
Duty = A/B
×
100 [%]
Center of movement
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
Fig. 5-3-5.
Fig. 5-3-6.
Содержание Handycam Vision CCD-TRV66E
Страница 10: ...1 1 CCD TRV66E TRV77E SECTION 1 GENERAL This section is extracted from instruction manual CCD TRV66E model ...
Страница 11: ...1 2 ...
Страница 12: ...1 3 ...
Страница 13: ...1 4 ...
Страница 14: ...1 5 ...
Страница 15: ...1 6 ...
Страница 16: ...1 7 ...
Страница 17: ...1 8 ...
Страница 18: ...1 9 ...
Страница 19: ...1 10 ...
Страница 20: ...1 11 ...
Страница 21: ...1 12 ...
Страница 22: ...1 13 ...
Страница 23: ...1 14 ...
Страница 24: ...1 15 ...
Страница 25: ...1 16 ...
Страница 26: ...1 17 ...
Страница 27: ...1 18 ...
Страница 28: ...1 19 ...
Страница 29: ...1 20 ...
Страница 30: ...1 21 ...
Страница 31: ...1 22 ...
Страница 32: ...1 23 ...
Страница 33: ...1 24E ...
Страница 46: ...CCD TRV66E TRV77E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 54: ...CCD TRV66E TRV77E 3 9 POWER BLOCK DIAGRAM 3 29 3 30 3 31 3 32E ...
Страница 56: ...CCD TRV66E TRV77E FRAME SCHEMATIC DIAGRAM 2 4 4 4 5 4 6 FRAME SCHEMATIC DIAGRAM 2 2 ...
Страница 71: ...CCD TRV66E TRV77E 4 53 4 54 STEADY SHOT SE 83 AV IN OUT PJ 92 ...
Страница 73: ...CCD TRV66E TRV77E 4 57 4 58 4 59 STEREO MIC AMP LASER LINK MA 351 ...
Страница 79: ...CCD TRV66E TRV77E 4 75 4 76 4 77 USER CONTROL CF 56 MR 8500 ...
Страница 82: ...CCD TRV66E TRV77E CCD TRV66E TRV77E 4 88E CONTROL SWITCH BLOCK FK 8500 SS 8500 ...