5-25
2. VCO Adjustment (PD-105 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
2
of CN5501 (VCO VOLTAGE)
Measuring Instrument
Oscilloscope (DC range)
Adjustment Page
E
Adjustment Address
C2, D8
Specified Value
A = 1.70
+0.03
V
–0.05
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 00.
4)
Select page: E, address: D8, change the data and set the VCO
VOLTAGE (A) to the specified value.
5)
Press the PAUSE button.
6)
Select page: E, address: D8 and read the data (D
D8
).
7)
Convert D
D8
to decimal notation, and obtain D
D8
'. (Refer to
Table 5-4-1. “Hexadecimal-decimal conversion table” of “5-4.
Service Mode”.)
8)
Calculate D
C2
' using following equation (decimal calculation),
convert it to a hexadecimal number, and input to page : E,
address : C2.
D
C2
' = D
D8
' – 27
9)
Press the PAUSE button.
10) Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
3. D range Adjustment (PD-105 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
3
of CN5501 (VG)
External trigger : Pin
4
of CN5501
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D6
Specified Value
A = 3.06 ± 0.05V
Note :
Press the DISPLAY button and erase the screen indictors on the
LCD screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 00.
4)
Select page: E, address: D6, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5)
Press the PAUSE button.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
A
2H
Pedestal
Pedestal
H
A
GND level
(0Vdc)
Fig. 5-1-17.
Fig. 5-1-18.
Содержание Handycam Vision CCD-TRV66E
Страница 10: ...1 1 CCD TRV66E TRV77E SECTION 1 GENERAL This section is extracted from instruction manual CCD TRV66E model ...
Страница 11: ...1 2 ...
Страница 12: ...1 3 ...
Страница 13: ...1 4 ...
Страница 14: ...1 5 ...
Страница 15: ...1 6 ...
Страница 16: ...1 7 ...
Страница 17: ...1 8 ...
Страница 18: ...1 9 ...
Страница 19: ...1 10 ...
Страница 20: ...1 11 ...
Страница 21: ...1 12 ...
Страница 22: ...1 13 ...
Страница 23: ...1 14 ...
Страница 24: ...1 15 ...
Страница 25: ...1 16 ...
Страница 26: ...1 17 ...
Страница 27: ...1 18 ...
Страница 28: ...1 19 ...
Страница 29: ...1 20 ...
Страница 30: ...1 21 ...
Страница 31: ...1 22 ...
Страница 32: ...1 23 ...
Страница 33: ...1 24E ...
Страница 46: ...CCD TRV66E TRV77E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 54: ...CCD TRV66E TRV77E 3 9 POWER BLOCK DIAGRAM 3 29 3 30 3 31 3 32E ...
Страница 56: ...CCD TRV66E TRV77E FRAME SCHEMATIC DIAGRAM 2 4 4 4 5 4 6 FRAME SCHEMATIC DIAGRAM 2 2 ...
Страница 71: ...CCD TRV66E TRV77E 4 53 4 54 STEADY SHOT SE 83 AV IN OUT PJ 92 ...
Страница 73: ...CCD TRV66E TRV77E 4 57 4 58 4 59 STEREO MIC AMP LASER LINK MA 351 ...
Страница 79: ...CCD TRV66E TRV77E 4 75 4 76 4 77 USER CONTROL CF 56 MR 8500 ...
Страница 82: ...CCD TRV66E TRV77E CCD TRV66E TRV77E 4 88E CONTROL SWITCH BLOCK FK 8500 SS 8500 ...