5-16
3-5-2. Clock Adjustments
1. IC1900 27MHz XTAL f
0
Adjustment (RJ-77 Board)
Set the sub-carrier frequency of the video output signal in the VTR
mode.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
#∞
of CN9921 on CB-61 board
(CK135) or R1114 (Pin
`⁄‚⁄
of
IC1101)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
98
Specified Value
f = 13500000 ± 68 Hz (NTSC)
f = 13500000 ± 68 Hz (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 98, change the data and set the clock
frequency (f) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 15, and set the data memorized at
step 2). Press the PAUSE button of the adjustment remote
commander.
6)
Select page: 0, address: 01, and set data: 00.
2. IC1900 VCO Operation Check (RJ-77 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Display data of page: 2, address: 0E
Measuring Instrument
Adjustment remote commander
Specified Value
“C0” to “FF”
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit2 to “0”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: 2, address: 05, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: D, address: B0, set data: 03, and press the PAUSE
button.
5)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
6)
Select page: D, address: B0, set data: 05, and press the PAUSE
button.
7)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
8)
Select page: D, address: B0, set data: 00, and press the PAUSE
button.
9)
Select page: 2, address: 05, set data: 00, and press the PAUSE
button.
10) Select page: D, address: 15, and set the data memorized at
step 2).
11) Select page: 0, address: 01, and set data: 00.
3. IC6101 41.85MHz VCO Operation Check (RJ-77 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Display data of page: 3, address: 39
Measuring Instrument
Adjustment remote commander
Specified Value
“37” to “C9”
Checking method:
1)
Select page: 3, address: 39, and check that the data is “37” to
“C9”.
Содержание GV-D300 Operating Instructions (primary manual)
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 ...
Страница 23: ...1 16 ...
Страница 24: ...1 17 ...
Страница 25: ...1 18 ...
Страница 26: ...1 19 ...
Страница 27: ...1 20E ...
Страница 30: ...2 3 2 4 CB 61 RJ 77 BOARDS 2 5 CONTROL SWITCH BLOCK FK 71 ...
Страница 33: ...2 6E 2 12 CIRCUIT BOARDS LOCATION ...
Страница 45: ...GV D300 D300E D900 D900E 4 29 4 30 4 31 AUDIO 1 CB 61 6 10 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 46: ...GV D300 D300E D900 D900E 4 33 4 34 AUDIO 2 CB 61 7 10 4 32 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 59: ...GV D300 D300E D900 D900E 4 81 4 82 MODE CONTROL RJ 77 9 9 See page 4 48 for RJ 77 BOARD printed wiring board ...
Страница 61: ...GV D300 D300E D900 D900E 4 85 4 86 4 87 AV IN OUT IO 62 4 88 ...
Страница 62: ...GV D300 D300E D900 D900E 4 89 4 90 4 91 4 92 MULTI CONNECTOR EX 34 ...
Страница 64: ...GV D300 D300E D900 D900E 4 96E CUSTOMER CONTROL CONTROL SW BLOCK FK 71 4 95 ...
Страница 142: ...3 BLOCK DIAGRAMS PAGE 3 3 3 1 OVERALL BLOCK DIAGRAM 1 2 PAGE 3 8 3 3 POWER BLOCK DIAGRAM ...
Страница 144: ...GV D300 D300E D900 D900E PAGE 4 89 SCHEMATIC DIAGRAM 5 6 MULTI CONNECTOR BACK LIGHT POWER EX 34 ...