5-12
3-4. SERVO SYSTEM ADJUSTMENTS
1. T Reel FG Duty Adjustment (RJ-77 Board)
Measurement Point
Display data of page: C, address: 6F
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
59, 6F
Specified Value
“01”, or “02” , “03”
Adjusting Method:
1)
Set the POWER switch to ON.
2)
Close the cassette compartment without inserting a cassette.
3)
Set the HOLD switch of the adjustment remote commander to
ON (SERVICE position).
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: C, address: 6A, set data: 10, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 3, address: 09, set data: 00, and press the PAUSE
button.
7)
Select page: 3, address: 01, set data: 1A, and press the PAUSE
button. (to start up automatic “T reel FG Duty Adjustments”.)
8)
Select page: 3, address: 02, and check that the data is changed
from “17” to “00”.
9)
Set the HOLD switch of the adjustment remote commander to
OFF, and wait more than 2 seconds. (so that the adjustment
data is automatically written in page: C, address: 59 and 6F).
10) Set the HOLD switch to ON.
11) Check that the data of page: 3, address: 04 and that of page: C,
address: 6F are the same.
12) Select page: C, address: 6F. If the data is “01”, or “02”, “03”, it
means that the automatic T reel FG duty adjustment has ended
normally.
13) Select page: C, address: 6A, set data: 00, and press the PAUSE
button of the adjustment remote commander.
14) Select page: 0, address: 01, and set data: 00.
15) Turn OFF the power supply.
2. Switching Position Adjustment (RJ-77 Board)
Mode
VTR Playback
Signal
SW/OL reference tape (XH2-3)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
4C, 4D, 4E, 4F
Specified Value
“00”.
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 0E, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data is changed
from “0E” to “00”.
4)
Select page: 3, address: 03, and check that the data is “00”.
5)
Set the HOLD switch of the adjustment remote commander to
OFF, and wait more than 2 seconds (so that the adjustment
data is automatically written in page: C, address: 4C to 4F).
6)
Set the HOLD switch of the adjustment remote commander to
ON.
7)
Select page: 0, address: 01, and set data: 00.
8)
Set to the stop mode.
9)
Turn OFF the power supply.
Содержание GV-D300 Operating Instructions (primary manual)
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 ...
Страница 23: ...1 16 ...
Страница 24: ...1 17 ...
Страница 25: ...1 18 ...
Страница 26: ...1 19 ...
Страница 27: ...1 20E ...
Страница 30: ...2 3 2 4 CB 61 RJ 77 BOARDS 2 5 CONTROL SWITCH BLOCK FK 71 ...
Страница 33: ...2 6E 2 12 CIRCUIT BOARDS LOCATION ...
Страница 45: ...GV D300 D300E D900 D900E 4 29 4 30 4 31 AUDIO 1 CB 61 6 10 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 46: ...GV D300 D300E D900 D900E 4 33 4 34 AUDIO 2 CB 61 7 10 4 32 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 59: ...GV D300 D300E D900 D900E 4 81 4 82 MODE CONTROL RJ 77 9 9 See page 4 48 for RJ 77 BOARD printed wiring board ...
Страница 61: ...GV D300 D300E D900 D900E 4 85 4 86 4 87 AV IN OUT IO 62 4 88 ...
Страница 62: ...GV D300 D300E D900 D900E 4 89 4 90 4 91 4 92 MULTI CONNECTOR EX 34 ...
Страница 64: ...GV D300 D300E D900 D900E 4 96E CUSTOMER CONTROL CONTROL SW BLOCK FK 71 4 95 ...
Страница 142: ...3 BLOCK DIAGRAMS PAGE 3 3 3 1 OVERALL BLOCK DIAGRAM 1 2 PAGE 3 8 3 3 POWER BLOCK DIAGRAM ...
Страница 144: ...GV D300 D300E D900 D900E PAGE 4 89 SCHEMATIC DIAGRAM 5 6 MULTI CONNECTOR BACK LIGHT POWER EX 34 ...