5-11
3-3.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Battery End Adjustment (CB-61 board)
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Recording
Signal
Color bar
Measurement Point
LCD display of the adjustment remote
Measuring Instrument
commander
Adjustment Page
D
Adjustment Address
28 to 2C, 37
Switch setting:
1)
LCD screen .................................................................... Open
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-3.
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote commander.
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
6)
Select page: 0, address: 01, and set data: 01.
7)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30 ± 0.01Vdc.
8)
Select page: 2, address: 51, read the data, and this data is named
Dref.
9)
Select page: D, address: 28, set data: Dref, and then press the
PAUSE button of the adjustment remote commander.
10) Select page: D, address: 37, set data: Dref, and then press the
PAUSE button of the adjustment remote commander.
11) Convert Dref to decimal notation, and obtain Dref’. (Refer to
Table 5-4-2. “Hexadecimal-decimal conversion table” of “5-4.
Service mode”)
12) Calculate D
29
', D
2A
’, D
2B
’ and D
2C
’ using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 29
D
29
' = Dref’+11
Address: 2A
D
2A
’ = Dref’+36
Address: 2B
D
2B
’ = Dref’+58
Address: 2C
D
2B
’ = Dref’+66
Note:
After setting each data, be sure to press the PAUSE button.
13) Select page: 0, address: 01, and set data: 00.
Digital voltmeter
Regulated power supply
5.30
±
0.01V
Battery terminal
GV-D300/D300E/D900/D900E
Fig. 5-3-3
Содержание GV-D300 Operating Instructions (primary manual)
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 ...
Страница 23: ...1 16 ...
Страница 24: ...1 17 ...
Страница 25: ...1 18 ...
Страница 26: ...1 19 ...
Страница 27: ...1 20E ...
Страница 30: ...2 3 2 4 CB 61 RJ 77 BOARDS 2 5 CONTROL SWITCH BLOCK FK 71 ...
Страница 33: ...2 6E 2 12 CIRCUIT BOARDS LOCATION ...
Страница 45: ...GV D300 D300E D900 D900E 4 29 4 30 4 31 AUDIO 1 CB 61 6 10 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 46: ...GV D300 D300E D900 D900E 4 33 4 34 AUDIO 2 CB 61 7 10 4 32 Refer to page 4 7 for CB 61 printed wiring board ...
Страница 59: ...GV D300 D300E D900 D900E 4 81 4 82 MODE CONTROL RJ 77 9 9 See page 4 48 for RJ 77 BOARD printed wiring board ...
Страница 61: ...GV D300 D300E D900 D900E 4 85 4 86 4 87 AV IN OUT IO 62 4 88 ...
Страница 62: ...GV D300 D300E D900 D900E 4 89 4 90 4 91 4 92 MULTI CONNECTOR EX 34 ...
Страница 64: ...GV D300 D300E D900 D900E 4 96E CUSTOMER CONTROL CONTROL SW BLOCK FK 71 4 95 ...
Страница 142: ...3 BLOCK DIAGRAMS PAGE 3 3 3 1 OVERALL BLOCK DIAGRAM 1 2 PAGE 3 8 3 3 POWER BLOCK DIAGRAM ...
Страница 144: ...GV D300 D300E D900 D900E PAGE 4 89 SCHEMATIC DIAGRAM 5 6 MULTI CONNECTOR BACK LIGHT POWER EX 34 ...