[SID Level Adjustment]
Condition:
Input signal
SVGA 60 Hz: RGB 0.7 Vp-p, 16 Step
Measurement point
MA-324 board CN206 pin
!§
Measuring equipment
Oscilloscope
Adjustment page
F
Adjustment address
78
Specification value
9.1 ± 0.1 Vp-p
Connection:
Adjustment Procedure:
(1)
Connect an oscilloscope to the CN206 pin
!§
on the MA-
324 board.
(2)
Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3)
On page: F, address: 78, change data with the PLAY and
STOP buttons and press the PAUSE button to write data so
that the
L
level of waveform on the oscilloscope satisfies
the specification value.
Adjustment and Adjustment Parts: MA-324 board (see page 3-15)
[PRG Level Adjustment]
Condition:
Input signal
SVGA 60 Hz: RGB 0.7 Vp-p, 16 Step
Measurement point
MA-324 board CN206 pin
!§
Measuring equipment
Oscilloscope
Adjustment page
F
Adjustment address
79
Specification value
6.8 ± 0.1 Vp-p
Connection:
Adjustment Procedure:
(1)
Connect an oscilloscope to the CN206 pin
!§
on the MA-
324 board.
(2)
Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3)
On page: F, address: 79, change data with the PLAY and
STOP buttons and press the PAUSE button to write data so
that the
M
level of waveform on the oscilloscope satisfies
the specification value.
Adjustment and Adjustment Parts: MA-324 board (see page 3-15)
[Black Limitte Adjustment]
Preparation:
Page
Address
Data
Remarks
F
11
01
Cancel protect of BRIGHT
F
7B
10
Change the BRIGHT level
Condition:
Input signal
SVGA 60 Hz: RGB ALL Black
Measurement point
MA-324 board CN206 pin
3
Measuring equipment
Oscilloscope
Adjustment page
F
Adjustment address
7A
Specification value
8.7 ± 0.1 Vp-p
Connection:
Adjustment Procedure:
(1)
Connect an oscilloscope to the CN206 pin
3
on the MA-
324 board.
(2)
Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3)
On page: F, address: 7A, change data with the PLAY and
STOP buttons and press the PAUSE button to write data so
that the
N
level of waveform on the oscilloscope satisfies
the specification value.
(4)
Set data: 1F to page F, address: 7B.
Adjustment and Adjustment Parts: MA-324 board (see page 3-15)
+
–
Oscilloscope
(DC range)
CN206 pin
!§
(P SIG B)
CN206 pin
9
(GND)
MA-324 Board
+
–
Oscilloscope
(DC range)
CN206 pin
!§
(P SIG B)
CN206 pin
9
(GND)
MA-324 Board
M
L
+
–
Oscilloscope
(DC range)
CN206 pin
3
(SIG G 1)
CN206 pin
9
(GND)
MA-324 Board
N
Black
Level
Black
Level
Содержание Glasstron PLM-S700E
Страница 3: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 862 932 ...
Страница 4: ...1 2 ...
Страница 5: ...1 3 ...
Страница 6: ...1 4 ...
Страница 7: ...1 5 ...
Страница 8: ...1 6 ...
Страница 9: ...1 7 ...
Страница 10: ...1 8 1 8 E ...