3-14
Page: E
Address: 08
E
08
= 08
Page: E
Address: 09
E
09
= 07
Page: E
Address: 0A
E
0A
= B8
Page: E
Address: 0B
E
0B
= 0B
Page: E
Address: 0C
E
0C
= 60
Page: E
Address: 0D
E
0D
= 54
Page: E
Address: 0E
E
0E
= 40
(18) Set data: 00 to page: 0, address: 01.
Note:
After setting each data, be sure to press the PAUSE button on the
adjusting remote commander.
[Battery Down Adjustment]
Mode
PC
RGB IN: No signal
Signal
PC AUDIO IN: No signal
VOLUME: Minimum
Measurement point
Displayed data on adj. remote commander
Measuring equipment
Adjustment page
F
Adjustment address
7E, 7F, 80, 81, 82, 83
Connection:
Referring to Fig. 3-4 (see page 3-15), connect the following equip-
ment.
(1)
Connect the regulated power supply and a digital voltmeter
to the battery terminal.
(2)
Connect the adjusting remote commander to the CN501 on
MA-324 board.
(3)
Connect a pattern generator to the RGB and PC AUDIO IN
terminal.
Menu Setting:
(Picture and tone quality standard setting) (see page 3-4)
Adjustment Procedure:
(1)
Adjust the output voltage of regulated power supply so that
the battery terminal voltage is 6.0 ± 0.01 Vdc.
(2)
Turn ON the POWER switch on the set.
(3)
Set data: 03 to page: 0, address: FF.
(4)
Set data: 0A to page: 2, address: 01.
(5)
Read data (ZZh) on page: 3, address: 7D.
(6)
Set data: 00 to page: 0, address: FF.
(7)
Set data: 01 to page: 0, address: 01. (Cancel F page protect)
(8)
Using the following formulas (calculation of hexadecimal
numbers), calculate the adjustment data and enter them to
respective adjustment addresses.
(Refer to 5. Data Processing on page 3-3)
Page: F
Address: 7E
F
7E
= ZZh
Page: F
Address: 7F
F
7F
= ZZh + 0Ah
Page: F
Address: 80
F
80
= ZZh + 0Dh
Page: F
Address: 81
F
81
= ZZh + 10h
Page: F
Address: 82
F
82
= ZZh + 16h
Page: F
Address: 83
F
83
= 01
(9)
Set data: 00 to page: 0, address: 01.
Note:
After setting each data, be sure to press the PAUSE button on the
adjusting remote commander.
[Change Adjustment]
Mode
PC
RGB IN: No signal
Signal
PC AUDIO IN: No signal
VOLUME: Minimum
Measurement point
Displayed data on adj. remote commander
Measuring equipment
Adjustment page
E, F
00, 01, 02, 03, 04, 05, 06, 07, 08, 09, 0A,
Adjustment address
0B, 0C, 0D, 0E (E page)
FE (F page)
Connection:
Referring to Fig. 3-4 (see page 3-15), connect the following equip-
ment.
(1)
Connect the regulated power supply and a digital voltmeter
to DC IN terminal.
(2)
Connect the adjusting remote commander to the CN501 on
MA-324 board.
(3)
Connect a PC to the RGB and PC ADUIO IN terminals.
Menu Setting:
(Picture and tone quality standard setting) (see page 3-4)
Adjustment Procedure:
(1)
Adjust the output voltage of regulated power supply so that
DC IN terminal voltage (DD-107 board J701) is 8.85 ± 0.01
Vdc.
(2)
Turn ON the POWER switch on the set.
(3)
Set data: 03 to page: 0, address: FF.
(4)
Set data: 0A to page: 2, address: 01.
(5)
Read data (XXh) on page: 3, address: 74.
(6)
Set data: 00 to page: 0, address: FF.
(7)
Set data: 01 to page: 0, address: 01. (Cancel E and F page
protect)
(8)
Using the following formulas (calculation of hexadecimal
numbers), calculate the adjustment data and enter them to
respective adjustment addresses.
(Refer to 5. Data Processing on page 3-3)
Page: E
Address: 00
E
00
= 01
Page: E
Address: 01
E
01
= XXh
Page: F
Address: FE
F
FE
= XXh – 39h
(9)
Set data: 00 to page: 0, address: 01.
(10) Connect the regulated power supply and a digital voltmeter
to the battery terminal.
(Keep connecting the regulated power supply to DC IN ter-
minal)
(11) Adjust the output voltage of regulated power supply so that
the battery terminal voltage is 8.35 ± 0.01 Vdc.
(12) Set data: 03 to page: 0, address: FF.
(13) Set data: 0A to page: 2, address: 01.
(14) Read data (YYh) on page: 3, address: 75.
(15) Set data: 00 to page: 0, address: FF.
(16) Set data: 01 to page: 0, address: 01.
(17) Using the following formulas (calculation of hexadecimal
numbers), calculate the adjustment data and enter them to
respective adjustment addresses.
(Refer to 5. Data Processing on page 3-3)
Page: E
Address: 02
E
02
= YYh
Page: E
Address: 03
E
03
= YYh – 02h
Page: E
Address: 04
E
04
= YYh – 55h
Page: E
Address: 05
E
05
= YYh + 02h
Page: E
Address: 06
E
06
= DC
Page: E
Address: 07
E
07
= 05
POWER SUPPLY BLOCK
Содержание Glasstron PLM-S700E
Страница 3: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 862 932 ...
Страница 4: ...1 2 ...
Страница 5: ...1 3 ...
Страница 6: ...1 4 ...
Страница 7: ...1 5 ...
Страница 8: ...1 6 ...
Страница 9: ...1 7 ...
Страница 10: ...1 8 1 8 E ...