3-4
6. Power ON Procedure for Adjustment
(1)
Connect an extension cable to the adjusting remote commander.
(2)
Set the
[PC]
or
[VIDEO]
mode on the set.
(3)
After making sure that the HOLD switch on the adjusting remote commander is not turned on (not at left (NOR) position), supply 8.4
Vdc to the DC IN (J701).
(With the HOLD switch at HOLD position, the initial operation of the set does not finish, disabling the POWER switch function.)
(4)
Turn ON the POWER switch on the set. Confirm that a green LED lights up.
(5)
Set the HOLD switch on the adjusting remote commander to the HOLD (right (ADJ)) position.
7. Adjustment Finishing Procedure
Order
Page
Address
Data
Description
Remarks
1.
E or F
Check if adjusted data are written correctly to the given page and address.
2.
2
FF
00
Set data 00 to given page and address.
Page 2: Reset
3.
0
FF
00
Page E or F: Write protect
4.
Set HOLD switch on adj. remote commander to NOR position.
8. Password Reset (for operation check of the set)
(1)
Turn the POWER switch on, then press the “Password Reset” at the bottom of Power Box to reset the password set by the customer.
(2)
Operating the jog dial, select “No” on the Password Set screen to set “disuse of password”.
Or,
Order
Page
Address
Data
Description
Remarks
1.
0
01
01
Set data 01 to given page and address.
Page E or F: Cancel protect
2.
E or F
04
FF
Set data FF to given page and address and press PAUSE.
Set disuse of password
Final:
After all adjustments and operation check finished, turn the POWER switch on, press the "Password Reset" at the bottom of Power Box, and
turn the POWER switch off.
9. EXT. VIDEO AUDIO mode: Turn the POWER switch on, and press and operate the jog dial from the initial screen.
Or,
Order
Page
Address
Data
Description
Remarks
1.
2
00
01
Set data 01 to given page and address.
2.
2
2B
00
Set data 00 to given page and address.
10. Picture and tone quality standard setting: Press the MENU button and set the BRIGHT control.
Or,
Set data 01 to page:0, address:01 to cancel the protect on page F.
Order
Page
Address
Data
Description
Remarks
F
7B
3F
Set data 3F to given page and address, and press PAUSE.
Ope. – Brightness: Center
F
53
40
Set data 40 to given page and address, and press PAUSE.
Ope. – Contrast: Center
F
50
3F
Set data 3F to given page and address, and press PAUSE.
Ope. – Hue: Center
F
51
3F
Set data 3F to given page and address, and press PAUSE.
Ope. – Density: Center
F
8C
02
Set data 02 to given page and address, and press PAUSE.
Ope.– Bass boost: 0,
VOL. limit: OFF
Volume (Display unit) – Maximum
Содержание Glasstron PLM-S700E
Страница 3: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 862 932 ...
Страница 4: ...1 2 ...
Страница 5: ...1 3 ...
Страница 6: ...1 4 ...
Страница 7: ...1 5 ...
Страница 8: ...1 6 ...
Страница 9: ...1 7 ...
Страница 10: ...1 8 1 8 E ...