2-14 (E)
FCB-IX47/47P
FCB-IX470/470P
2.
ADJUSTMENT
2. SYNC Level Adjustment (VC-211 board)
Set the Y signal output level.
Subject
All black
Measurement Point
Pin
6
of CN301
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
49
Specified Value
A = 286
±
5mV (NTSC)
A = 300
±
5mV (PAL)
Note:
Terminate at 75
Ω
resistor and measure.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 49, change the data and set the SYNC
level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
2-3.
CAMERA ADJUSTMENTS
1. 28 MHz Origin Oscillation Adjustment (VC-211 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin
!™
of IC101
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
2C
Specified Value
Pin
!™
of IC101 :
f=14.318181MHz
±
68Hz (NTSC)
f=14.187500MHz
±
68Hz (PAL)
Note 1:
NTSC MODEL: FCB-IX47/470
PAL MODEL:
FCB-IX47P/470P
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 2C, change the data and set the clock
frequency(f) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
A
H
Содержание FCB-IX47
Страница 1: ...COLOR VIDEO CAMERA FCB IX47 47P FCB IX470 470P SERVICE MANUAL ...
Страница 2: ......
Страница 5: ...1 1 FCB IX47 47P FCB IX470 470P http getMANUAL com ...
Страница 6: ...1 2 FCB IX47 47P FCB IX470 470P ...
Страница 7: ...1 3 FCB IX47 47P FCB IX470 470P ...
Страница 8: ...1 4 FCB IX47 47P FCB IX470 470P ...
Страница 9: ...1 5 FCB IX47 47P FCB IX470 470P ...
Страница 10: ...1 6 FCB IX47 47P FCB IX470 470P ...
Страница 34: ......
Страница 42: ......
Страница 63: ...VECTORSCOPE SCALE Burst position For NTSC model Burst position For PAL model ...