2-5 (E)
FCB-IX47/47P
FCB-IX470/470P
2.
ADJUSTMENT
2-1-5. Adjusting Remote Commander
The adjusting remote commander is used for changing the calcula-
tion coefficient in signal processing, EVR data, etc. The adjusting
remote commander performs bi-directional communication with the
unit. The resultant data of this bi-directional communication is writ-
ten in the non-volatile memory.
1. Using the adjusting remote commander
1) Connect the adjusting remote commander to the LANC termi-
nal (VC-211 board CN704) with Adjustment Commander Re-
lay Jig.
(Note) The Relay Jig will have Pin
1
coincide with Pin
1
of the
CN704.
2) Adjust the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
If it has been properly connected, the LCD on the adjusting remote
commander will display as shown in Figure.
3) Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT button is
pressed, and decreases when the EDIT SEARCH– button is
pressed. There are altogether 16 pages, from 0 to F.
Page
Data
Address
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
• Changing the address
The address increases when the FF (
)
) button is pressed,
and decreases when the REW (
0
) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (
(
) button is pressed,
and decreases when the STOP (
p
) button is pressed.
There are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (D, E, F page) in the nonvolatile memory.
(The new adjustment data will not be recorded in the nonvola-
tile memory if this step is not performed.)
4) Select page: 0, address: 01, and set the data to 01, and enables
Page D and E, F to be adjusted.
5) After completing all adjustments, set data: 00 to page: 0, ad-
dress: 01 and turn off the main power supply (8.4V) once.
2. Precautions upon using the adjusting remote
commander
Mishandling of the adjusting remote commander may erase the cor-
rect adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments
and new adjustment data after each adjustment.
Содержание FCB-IX47
Страница 1: ...COLOR VIDEO CAMERA FCB IX47 47P FCB IX470 470P SERVICE MANUAL ...
Страница 2: ......
Страница 5: ...1 1 FCB IX47 47P FCB IX470 470P http getMANUAL com ...
Страница 6: ...1 2 FCB IX47 47P FCB IX470 470P ...
Страница 7: ...1 3 FCB IX47 47P FCB IX470 470P ...
Страница 8: ...1 4 FCB IX47 47P FCB IX470 470P ...
Страница 9: ...1 5 FCB IX47 47P FCB IX470 470P ...
Страница 10: ...1 6 FCB IX47 47P FCB IX470 470P ...
Страница 34: ......
Страница 42: ......
Страница 63: ...VECTORSCOPE SCALE Burst position For NTSC model Burst position For PAL model ...