2-15 (E)
FCB-IX47/47P
FCB-IX470/470P
2.
ADJUSTMENT
3. BURST Level Adjustment (VC-211 board)
Set the chroma signal output level.
Subject
All black
Measurement Point
Pin
6
of CN301
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
4B
Specified Value
A = 286
±
5mV (NTSC)
A = 300
±
5mV (PAL)
Note:
Terminate at 75
Ω
resistor and measure.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 4B, change the data and set the burst
level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: 0, address: 01, and set data: 00.
4. G-CAM flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Not required
Measurement Point
Display data of page 1 of the adjusting
remote commander (Note 1)
Measuring Instrument
Adjustment Page
F
Adjustment Address
21
Specified Value
S1 S2
Note 1.
Displayed data of page 1 of the adjusting remote com-
mander.
1 : XX : XX
n
S2
n
S1
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 16.
3) Select page 1 of the adjusting remote commander, and compare
the higher 2 digits (S1) and lower 2 digits (S2) of the 4-degits
display data.
When S1<S2
Perform steps 5) onwards.
When S1 S2
Perform steps “Processing after Completing Adjustments”.
4) Select page: F, address: 21, set data: 52, and press the PAUSE
button of the adjusting remote commander.
A
H
5) Select page: 0, address: 03, and set data: 00.
6) Select page: 0, address: 01, and set data: 00.
Before Modify data
After Modified data
52
D2
D2
52
Содержание FCB-IX47
Страница 1: ...COLOR VIDEO CAMERA FCB IX47 47P FCB IX470 470P SERVICE MANUAL ...
Страница 2: ......
Страница 5: ...1 1 FCB IX47 47P FCB IX470 470P http getMANUAL com ...
Страница 6: ...1 2 FCB IX47 47P FCB IX470 470P ...
Страница 7: ...1 3 FCB IX47 47P FCB IX470 470P ...
Страница 8: ...1 4 FCB IX47 47P FCB IX470 470P ...
Страница 9: ...1 5 FCB IX47 47P FCB IX470 470P ...
Страница 10: ...1 6 FCB IX47 47P FCB IX470 470P ...
Страница 34: ......
Страница 42: ......
Страница 63: ...VECTORSCOPE SCALE Burst position For NTSC model Burst position For PAL model ...