2-16 (E)
FCB-IX47/47P
FCB-IX470/470P
2.
ADJUSTMENT
5. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of TV monitor
(Note 3)
Measuring Instrument
Adjustment Page
F
Adjustment Address
2F, 30
Specified Value
90 to 94 during IRIS OPEN (Note 1)
19 to 1D during IRIS CLOSE (Note 2)
Note 1:
Select page: 2, address: 01, set data: 01, and press the
PAUSE button of the adjusting remote commander.
Note 2:
Select page: 2, address: 01, set data: 03, and press the
PAUSE button of the adjusting remote commander.
Note 3:
DDS display data of TV monitor.
00 00XX
n
Object data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 03.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: F, address: 30, set data: 80, and press the PAUSE
button.
6) Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
7) Read the DDS display data (the bottom two digits of the display
data at the bottom right of the TV monitor), and this data is
named K
2
.
8) Select page: F, address: 2F, set data: 30, and press the PAUSE
button.
9) Read the DDS display data, and this data is named K
1
.
10)Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
11)Read the DDS display data, and this data is named W
1
.
12)Select page: F, address: 2F, set data: 40, and press the PAUSE
button.
13)Read the DDS display data, and this data is named W
2
.
14)Convert W
1
, W
2
, K
1
, K
2
, to decimal notation, and obtain W
1
' ,
W
2
' , K
1
' , K
2
'. (Refer to Table 5-1-2. “Hexadecimal notation -
decimal notation conversion table”.)
15)Calculate X
1
' using the following equations (decimal notation
calculation).
A’= W
2
'+ K
1
'– W
1
'– K
2
'
Equation 1
B’= W
1
' – K
1
'
Equation 2
X
1
'=[1904+(48 x A’)–(16 x B’)] / A’
Equation 3
16)Convert X
1
' to hexadecimal notation, and obtain X
1
.
(Round off to one decimal place)
17)Select page: F, address: 2F, set data: X
1
, and press the PAUSE
button.
18)Select page: 2, address: 01, and set data: 01, and press the PAUSE
button.
19)Select page: F, address: 30, change the data and adjust the DDS
display data to “92”.
20) Press the PAUSE button of the adjusting remote commander.
21) Select page: 2, address: 01, and set data: 03, and press the PAUSE
button.
22) Read the DDS display data, and this data is named K
0
. If K
0
lies
within the “19” to “1D” range, perform “Processing after com-
pleting adjustments”. If it is lies outside the range, perform the
following adjustments.
23) Convert K
0
to decimal notation, and obtain K
0
'.
24) Calculate X
2
' using the following equations (decimal notation
calculation).
C’= 146 – B’– K
0
'
Equation 4
X
2
'=[(119 – B’) x ( X
1
' – 48)+(48 x C’)] / C’
Equation 5
( X
1
' and B’ are values obtained from equations 2) and 3) )
25) Convert X
2
' to hexadecimal notation, and obtain X
2
.
(Round off to one decimal place)
26) Select page: F, address: 2F, set data: X
2
, and press the PAUSE
button.
27) Select page: 2, address: 01, set data: 03, and press the PAUSE
button.
28) Select page: F, address: 30, change the data and adjust the DDS
display data to “1B”.
29) Press the PAUSE button of the adjusting remote commander.
30) Select page: 2, address: 01, set data: 01, and press the PAUSE
button.
31) Check the DDS display data lies within the “90” to “94” range.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button.
4) Select page: 0, address: 03, and set data: 00.
Содержание FCB-IX47
Страница 1: ...COLOR VIDEO CAMERA FCB IX47 47P FCB IX470 470P SERVICE MANUAL ...
Страница 2: ......
Страница 5: ...1 1 FCB IX47 47P FCB IX470 470P http getMANUAL com ...
Страница 6: ...1 2 FCB IX47 47P FCB IX470 470P ...
Страница 7: ...1 3 FCB IX47 47P FCB IX470 470P ...
Страница 8: ...1 4 FCB IX47 47P FCB IX470 470P ...
Страница 9: ...1 5 FCB IX47 47P FCB IX470 470P ...
Страница 10: ...1 6 FCB IX47 47P FCB IX470 470P ...
Страница 34: ......
Страница 42: ......
Страница 63: ...VECTORSCOPE SCALE Burst position For NTSC model Burst position For PAL model ...