background image

Sony Corporation

SERVICE MANUAL

Revision History

 

Link (English)

 

SPECIFICATIONS

 

Link (Japanese)

 

SPECIFICATIONS

 

サービス専用光学ブロック交換時の注意

 

SERVICE NOTE

 

DISASSEMBLY

 

SERVICE NOTE

 

DISASSEMBLY

 

REPAIR PARTS LIST

 

ADJUSTMENTS

 

REPAIR PARTS LIST

 

ADJUSTMENTS

分解図につきましては,英語版を

ご参照ください。

SELP1650 (E 3.5-5.6/PZ 16-50 OSS) (E PZ 16-50mm F3.5-5.6 OSS)

NOTE ON REPLACEMENT OF SERVICE 
EXCLUSIVE OPTICS BLOCK

983469314.pdf

2013I08-1

© 2013.09

Published by Sony Techno Create Corporation

Ver. 1.3  2013.09

US Model

Canadian Model

AEP Model

Chinese Model

Japanese Model

9-834-693-14

SELP1650

(E 3.5-5.6/PZ 16-50 OSS) (E PZ 16-50mm F3.5-5.6 OSS)

INTERCHANGEABLE LENS

Revised-3

Replace the previously issued
SERVICE MANUAL 9-834-693-13
with this Manual.

Ver.

Date

History

Contents

S.M. Rev.

issued

1.0

2012.11

Official Release

1.1

2012.11

Revised-1
(A1 12-283)

•  Change of DISASSEMBLY.
 English: 

Page 2-2

2-4

2-5

2-6

 Japanese: 

Page 2-2

2-4

2-5

2-6

•  Change of REPAIR PARTS LIST.
 

Page 3-1

Yes

1.2

2013.04

Revised-2
(A2 12-344)

  Change of “NOTE ON REPLACEMENT OF SERVICE EXCLUSIVE 

OPTICS BLOCK”

 

Page 3

 Change of DISASSEMBLY

 English: 

Page 2-1

,

 2-2

,

 2-4

,

 2-6

 Japanese: 

Page 2-1

,

 2-2

,

 2-4

,

 2-6

 Change of REPAIR PARTS LIST

 

Page 3-1

 Addition of Section 4. ADJUSTMENTS

 English: 

Page 4-1

,

 4-2

,

 4-3

,

 4-4

,

 4-5

,

 4-6

 Japanese: 

Page 4-1

,

 4-2

,

 4-3

,

 4-4

,

 4-5

,

 4-6

Yes

1.3

2013.09

Revised-3
(A3 13-090)

•  Change of REPAIR PARTS LIST.
 

Page 3-1

 Change of ADJUSTMENTS.

 English: 

Page 4-1

 Japanese: 

Page 4-1

Yes

Содержание E 3.5-5.6/PZ 16-50 OSS

Страница 1: ...SS INTERCHANGEABLE LENS Revised 3 Replace the previously issued SERVICE MANUAL 9 834 693 13 with this Manual Ver Date History Contents S M Rev issued 1 0 2012 11 Official Release 1 1 2012 11 Revised 1 A1 12 283 Change of DISASSEMBLY English Page 2 2 2 4 2 5 2 6 Japanese Page 2 2 2 4 2 5 2 6 Change of REPAIR PARTS LIST Page 3 1 Yes 1 2 2013 04 Revised 2 A2 12 344 Change of NOTE ON REPLACEMENT OF SE...

Страница 2: ... shown above for equivalent 35mm format focal length and angle of view are for Interchangeable Lens Cameras equipped with an APS C sized image sensor 2 Minimum focus is the shortest distance from the image sensor to the subject Included items Lens 1 Front lens cap 1 Rear lens cap 1 Set of printed documentation Design and specifications are subject to change without notice is a trademark of Sony Co...

Страница 3: ... Flag OFF S of E Mount Lens Adjustment Adjustment Application for Service Note The lens cannot be detected when the E mount lens is connected to the NEX 3 5 C3 without releasing the specified flag Displayed as F ENGLISH JAPANESE サービス専用光学ブロック交換時の注意 サービス専用光学ブロックを交換した際には E mountレンズをNEX 3 5 C3に接続し 以下の方法で専用フラグ解除を行ってくださ い レンズ調整プログラム E Mount Lens Adjustment Adjustment Application for Service の Service Fl...

Страница 4: ... not to let solder bridges occur such as on IC pins etc Be sure to control soldering iron tips used for unleaded solder and those for leaded solder so they are managed separately Mixing unleaded solder and leaded solder will cause detachment phenomenon 1 4 SAFETY CHECK OUT After correcting the original service problem perform the following safety checks before releasing the set to the customer 1 C...

Страница 5: ... or some pieces of gilt may be left inside Notches Holes How to Use Universal wrench J 6082 609 A Chip A for universal wrench J 6082 609 1 Chip B for universal wrench J 6082 609 2 Attach the chip A or chip B to the universal wrench For the notches For the holes UNIVERSAL WRENCH In case of the following notches or holes are located in the lens block etc during disassembling assembling the lens Use ...

Страница 6: ...two holes out of three holes of the Operation Barrel Assy 2 Turn the outside of the Operation Barrel Assy to find the position where the tip of Chip B can be fully inserted and check that the outside and the inside of the Operation Barrel Assy turn simultaneously 3 Turn the outside and the inside of the Operation Barrel Assy counterclockwise until you feel a click and remove the Operation Barrel A...

Страница 7: ...utside Inside Operation Barrel Assy Hole Operation Barrel Assy HELP02 1 Fold the Flexible Board of the Switch Assy as shown below Switch Assy Flexible board 2 Insert the Flexible Board of the Switch Assy into the hole in the Outer Barrel Assy 3 Slide the hook near the mark on the Switch Assy in the direction of arrow 2 to install the hook 4 Install the hook far from the mark Switch Assy Flexible b...

Страница 8: ...sy to the Optical Unit from the mounting side while inserting the three projections of the 1st Lens Assy into the inner grooves of the Outer Barrel Assy Outer Barrel Assy Flexible board Grooves Groove Projections Projection Optical Unit Switch Assy Ver 1 2 2013 04 HELP05 Fixed Ring 1st Lens Assy 2nd Lens Assy 3rd Lens Assy Optical Unit Zoom Cam Tube 1 Attach the Fixed Ring to the Zoom Cam Tube and...

Страница 9: ...the 2nd Lens Assy with the two concaves of the 1st Lens Assy and then insert the three projections of the 2nd Lens Assy into the three grooves of the 1st Lens Assy arrow 1 while maintaining the state of the 2nd Lens Assy 3rd Lens Assy Fixed Ring and Zoom Cam Tube shown below 5 When the 2nd Lens Assy is fully inserted into the 1st Lens Assy the three projections of the 1st Lens Assy are inserted in...

Страница 10: ... HELP06 Adhesive bond B 60 J 6082 616 A 1 Attach the 1st Lens Assy to the 1st Moving Frame while positioning them as shown below 2 Put the two 1st Holding Springs 3 Apply bond B 60 to the two screw threads of the 1st Moving Frame 4 Position the 1st Light Shield Ring as shown below attach it to the 1st Moving Frame and then firmly turn the 1st Light Shield Ring counterclock wise Apply the adhesive ...

Страница 11: ...the original one Items marked are not stocked since they are seldom required for routine service Some delay should be anticipated when ordering these items The mechanical parts with no reference number in the exploded views are not supplied DISASSEMBLY ENGLISH DISASSEMBLY JAPANESE 26 1 2 4 18 22 21 6 7 15 11 8 12 12 16 16 12 13 17 17 14 9 3 24 Note 1 2 ns Note 1 2 ns 19 20 25 25 23 ns 10 5 5 5 ns ...

Страница 12: ...3 4 434 750 11 取扱説明書 ドイツ語 オランダ語 スェーデン語 イタリア語 ポルトガル語 953 4 434 750 21 取扱説明書 ロシア語 ウクライナ語 中国語 繁体字 韓国語 アラビア語 Ref No Part No Description 901 X 2584 679 1 Front lens cap 902 4 159 701 01 Rear lens cap 903 4 434 750 01 Instruction Manual JAPANESE ENGLISH FRENCH SPANISH SIMPLIFIED CHINESE 903 4 434 750 11 Instruction Manual GERMAN DUTCH SWEDISH ITALIAN PORTUGUESE 903 4 434 750 21 Instruction Manual RUSSIA...

Страница 13: ...wer check chart Focus Chart_A3 pdf 40 inch LCD monitor Full HD Camera NEX 3 5 Tripod adaptor optional NOTE The lens adjustment program FB adjustment chart and Resolving power check chart can be downloaded from the TISS homepage For partial adjustments operations on lens side are required Prepare a larger tripod to prevent the lens from wobble Note1 Personal computer The SeusEX must be installed in...

Страница 14: ...adjustment program E Mount Lens Adjustment zip from the ESI homepage 2 Double click the setup exe file 3 The installer screen appears then click the Next button Fig 4 2 2 NOTE Make sure to perform the installation only by the management Do not change the folder to be installed in TELE end Within 10 mm Flange back adjustment jig J 6082 563 A FB Adjustment chart or Siemens star chart J 6080 875 A AC...

Страница 15: ... the specified plug before using the E Mount Lens Adjustment Make sure to disconnect the AC adaptor after finishing the adjustment including the case when stops due to an error SeusEX will start when the E Mount Lens Adjustment is started 1 Start the E Mount Lens Adjustment 2 Click the Connect button and check if the connection status becomes Connect 2 Finishing the E Mount Lens Adjustment 1 Click...

Страница 16: ...equired item are complete click the Iris Close button 7 Click the button on the upper right of the main window to finish E Mount Lens Adjustment 8 Turn off the power of camera NOTE If the PUSH ENTER does not disappear even after pressing the ENTER key press it again Do not touch the focus ring when performing operations on lens side as the focus is on status during adjustment Ver 1 2 2013 04 2 Met...

Страница 17: ...T Tools and Equipments Resolving power check chart Note Download the resolving power check chart from the TISS homepage Camera NEX 3 5 Note Prepare the resolving power check chart according to the procedure shown below 1 Download the Focus Chart_A3 pdf from TISS homepage 2 Print the Focus Chart_A3 pdf sized by 100 4 5 1 Preparations 1 Set the Shooting Mode to the Aperture Priority mode and set the...

Страница 18: ...080 875 A Camera NEX 5 40 inch LCD monitor Full HD 4 6 1 Preparations 1 Set the siemens star chart on the flange back adjustment jig NOTE Set the siemens star chart with the center to be 200 to 400 lux or 35 to 65 cd m2 For the siemens chart use a light source free from flickering 2 On TELE end set the distance from the lens of flange back adjustment jig to the checking lens to be within 10 mm 3 M...

Страница 19: ...ッドフリーマーク 無鉛半田は 下記の点に注意して使用してください 注意 半田こてを長く当てすぎると 基板のパターン 銅箔 がはがれてしまうことがありますので 注意してください また 従 来の半田よりも粘性が強いため IC端子などが半田ブリッジしないように注意してください 半田こてのこて先は 必ず無鉛半田用と有鉛半田用に分けて管理してください 無鉛半田と有鉛半田が混在すると剥離現象が発生してしまいます 1 4 SAFETY CHECK OUT サービス 点検時には次のことにご注意ください 1 注意事項をお守りください サービスのとき特に注意を要する個所については キャビネット シャーシ 部品などにラベルや捺印で注意事項を表示してい ます これらの注意書き及び取扱説明書等の注意事項を必ずお守りください 2 指定部品のご使用を セットの部品は難燃性や耐電圧など安全上の特性を持ったものとなっていま...

Страница 20: ...でください フレキシブル基板のメッキ部に過度な負担をかけないでください 先端の剥がれたメッキ部は カットして除去する メッキ破片がコネクタ内に 残っている場合もあるので注意 B 60 ボンド B 60 J 6082 616 A 副資材について ボンド ロックタイト460 または相当品 ロックタイト460 または相当品 切り欠き 穴 使用方法 レンズ専用治具について 分解 または組み立て時に レンズブロック等に以下のような切り欠き または穴がある場合は レンズ専用治具を使用してください レンズ専用治具 J 6082 609 A レンズ専用治具 チップA J 6082 609 1 レンズ専用治具 チップB J 6082 609 2 レンズ専用治具にチップA またはチップBを取り付ける 切り欠き用 穴用 チップA チップB レンズ専用治具 切り欠き 穴 チップ チップ 切り欠き または 穴の幅に...

Страница 21: ...向に外側部と内側部をクリック感があるところまで回転させて 操作環Assyを取り外す 穴 外側部 内側部 操作環部組の外し方 Note 2 固定保持環Assy取り外し時の注意 Note 1 MF PR押さえ板の長いツメ側を固定保持環Assyの 内側の矢印方向に押して外す 固定保持環Assyを外す際 光学部組が分解されてしまう場合があります 光学部組を分解させないよう固定保持環Assyを外す際は必ず下記の手順で 取り外してください 1 Note 2 を参照し 先に操作環Assyを外す 2 ワイド端の状態で固定保持環Assyのねじ4本を外す 3 光学部組のワイド端の状態を必ず保持しながら 固定保持環Assyを取り外す MF PR押さえ板の外し方 Note 3 ワイド端の状態を必ず保持する 操作環Assy Note 1 2 1群前板 前外装カバー 1群遮光環 1群移動枠 1群レンズ部組 1群部組 ...

Страница 22: ...確認する 5 操作環Assyの外側部と内側部を時計方向にクリック感があるところまで回転させる 6 操作環Assyの動作を確認する 操作環Assy 操作環Assy 穴 外側部 内側部 HELP02 1 スイッチ部組のフレキに図のように折り癖を付ける スイッチ部組 フレキ 2 固定保持環Assyの穴にスイッチ部組のフレキを差し込む 3 スイッチ部組の指標に近いフックを矢印2方向にスライドさせて取り付ける 4 指標から遠いフックを取り付ける スイッチ部組 フレキ 穴 固定保持環Assy 2 2 3 1 1 スイッチ部組 スイッチ部組 指標 指標 フック フック 5 スイッチ部組のフレキを固定保持環Assy内側のスリット2箇所に差し込み フレキの粘着部を溝に貼り付ける 注意 固定保持環Assy外側の穴2箇所に フレキのセンサー部がはまっていることを確認してください 粘着部 スリット スイッチ部組 ...

Страница 23: ...前板 基準 基準 3 HELP04 固定保持環のスイッチ部組とフレキの位置を合わせて 1群部組の突起3箇所を固定保持環の内径に挿入させながら 固定保持環 Assyをマウント側から光学部組に組み付けてください 光学部組 固定保持環Assy スイッチ部組 フレキ 突起 溝 溝 突起 HELP05 3群部組 2群部組 ズームカム環 光学部組 1群部組 固定環 1 ズームカム環に固定環を取り付け ズームリセットPI保持部とギアが下図の位置になるまで 固定環を回転させる 注意 固定環のバヨネットが勘合していることを確認してください ズームカム環 固定環 固定環 ズームリセット PI保持部 ギア部 バヨネット Ver 1 2 2013 04 ...

Страница 24: ... 2群部組 3群部組 2群部組 3群部組 固定環 ズームカム環 固定環 ズームカム環 突起 突起 突起 溝 内周 溝 内周 溝 内周 突起 コネクタ 4 2群部組の凸部2箇所と1群部組の凹部2箇所の位置を合わせて 2群部組 3群部組 固定環 ズームカム環を下図の状態 手順4 の 状態 に保持したまま 2群部組の突起3箇所を1群部組の溝3箇所に挿入する 矢印1 5 2群部組を1群部組の奥まで挿入すると 1群部組の突起3箇所がズームカム環の溝入り口3箇所に挿入される 矢印2 ズームカム環を矢印方向に回転させるが 最後まで回転させず 1群部組の突起がズームカム環の溝のUターン位置にきたら いっ たんその状態を保持する 凹部 対物側 接眼側 凸部 2群部組 3群部組 固定環 ズームカム環 ズームカム環 溝のUターン位置 2群部組 2群部組 突起 溝 溝入り口 溝 溝 突起 突起 1群部組 1群部組...

Страница 25: ...ド端の状態にする このとき固定環の穴3箇所に2群部組の突起3箇所を通り抜けさせる A ズームカム環 1群部組 2群部組の突起 HELP06 ボンド B 60 J 6082 616 A 1 図のように位置を合わせ 1郡レンズ部組を1郡移動枠に取り付ける 2 1郡押さえばね2個を置く 3 1郡移動枠のねじ部2箇所にボンド B 60 を塗布する 4 図のように位置を合わせ 1郡遮光環を移動枠に取り付け 反時計方向に締め付ける 1郡レンズ部組 クリック部 1郡遮光環 1郡遮光環 1郡移動枠 穴側面 切り欠き 1郡押さえばね 切り欠き 穴 小 ボンド B 60 を塗布 Ver 1 2 2013 04 ...

Страница 26: ...ト SEL18200 FB Adjustment Chart pdf 撮影解像力確認チャート Focus Chart A3 pdf 40インチ液晶モニタ Full HD カメラ NEX 3 5 三脚 任意 注意 レンズ調整プログラム FB調整チャートおよび撮影解像力確認チャートは TISSホームページからダウンロード可能です 一部の調整において レンズ側での操作が必要となりますので レンズを操作した際に ぐらつかないよう大きな三脚をご用意願います Note1 パーソナルコンピュータ SeusEX がインストール済みのもの OS Windows XP Home Professional SP2 以降 Vista 7 RAM 256 MB またはそれ以上を推奨 Windows XP 7 1 GB またはそれ以上を推奨 Windows Vista USB port USB 2 0 を推奨 USB...

Страница 27: ...ムページより レンズ調整プログラム E Mount Lens Adjustment zip をダウンロードする 2 setup exeをダブルクリ ックする 3 インストーラー画面が表示されるので 次へ ボタンをクリ ックする Fig 4 2 2 Fig 4 2 1 フランジバック 調整用治具 10mm以内 被検レンズ Tele端 パーソナルコンピュータ SeusExがインストール済みのもの OS Windows XP Home Professional SP2以降 Vista 7 RAM 256MBまたはそれ以上を推奨 Windows XP 7 1GBまたはそれ以上を推奨 Windows Vista USBポート USB 2 0を推奨 USB 1 1でも使用可能 ポートは2個必要 Run time NET Framework 2 0 NET Framework 2 0がインストールされて...

Страница 28: ...atusが Connect に変化するこ とを確認する 2 E Mount Lens Adjustmentの終了 1 Disconnect ボタンをクリ ックし Connection Statusが Disconnect に変化するこ とを確認する 2 メインウインドウ右上の ボタンをクリ ックし終了する 4 3 E Mount Lens Adjustment 5 インストール開始画面が表示されるので 次へ ボタンをク リ ックし インストールを開始する 6 インストールが完了すると 下記画面が表示されるので 閉じる ボタンをク リ ックする 7 デスク トップにE Mount Lens Adjustment Adjustment Application for Service のショートカッ トアイコンが作成される Fig 4 2 4 Fig 4 2 5 Fig 4 2 6 Fig 4 ...

Страница 29: ...以降を参照願います 5 調整が終了すると ポップアップウィ ンドウにて FINISHED と表示されるので OK ボタンをク リ ックする Fig 4 3 3のようにMessage Historyへ調整結果が表示されます Clear ボタンをクリ ックすると Message Historyに表示されている履歴が消去されます 注意 ENTERを押しても PUSH ENTER が消えない場合は 再度ENTERを押してく ださい 調整時はフォーカスが となりますので レンズ側での操作の際にフォーカスリングを触らないでく ださい Fig 4 3 3 Ver 1 2 2013 04 2 Flange Back S の調整方法 Flange Back S の項目については レンズ側での操作が必要となります 以下に調整方法を掲載します 1 Fig 4 3 4のポップアップウインドウが表示されるので 調整...

Страница 30: ...2項 限界レベル付近 OKレベル NGレベル OKレベル NGレベルまたはピントズレ 中心と周辺4箇所を等倍で確認してください Fig 4 5 2 Fig 4 5 1 266 5 mm 200 mm 使用機器 治工具 撮影解像力確認チャート Note 撮影解像力確認チャートはTISS ホームページからダウンロードしてく ださい カメラ NEX 3 5 Note 撮影解像力確認チャートを 以下の手順にて準備してく ださい 1 TISSホームページから Focus Chart A3 pdf をダウンロードする 2 Focus Chart A3 pdf を100 の大きさで印刷する 1 撮影モードを絞り優先にし 絞り値を開放にする 2 撮影距離が1300mm イメージャー面 になるよう設置し ズームをTELE端にする 3 ピントを合わせてチャートが上下左右均等になるように配置する 4 5 撮影解...

Страница 31: ...機器 治工具 フランジバック調整用治具 J 6082 563 A ジーメンススターチャート J 6080 875 A カメラ NEX 5 40インチ液晶モニタ Full HD 4 6 フランジバックの確認 4 6 1 準備 1 フランジバック調整用治具にジーメンススターチャートをセッ トする 注意 ジーメンススターチャートの中心部で 200 400lux または 35 65cd m2 になるようにしてく ださい ジーメンススターチャートは光源ムラがないようにしてく ださい 2 TELE端にしたとき フランジバック調整用治具のレンズから被検レンズの先端まで 10mm 以内にセッ トする 3 マニュアルフォーカスにてLCDの中心に ジーメンススターチャートの中心が来るように正対させる 4 カメラを以下のモードに設定する 動画 AVCHD 5 再度 被検レンズを装着し直す フォーカスが となる ...

Страница 32: ...93571 2nd 6504387 3rd 8197449 1st 6504386 2nd 8197448 Silver SELP1650 Made in CHINA All 3rd 0010800 Black SELP1650 Made in CHINA All 3rd 0409642 Silver SYMPTOM A shock could cause the Stationary Barrel to crack and the lens cannot be recognised by the camera REQUIRED PART TOOL SOFTWARE 4 426 821 03 4 594 306 01 Stationary Barrel 4 426 820 01 4 594 483 01 Zoom Cam Barrel SOLUTION When exchanging a ...

Страница 33: ...this case the padding interferes with the Zoom Cam Barrel Therefore the Zoom Cam Barrel has been modified REQUIRED PART TOOL SOFTWARE The following part will be provided as a discrete part 4 426 821 01 4 426 821 02 1st improvement 4 426 821 03 2nd improvement 4 594 306 01 3rd improvement Stationary Barrel A 1897 552 A A 1897 552 B 1 Group Block Assy BLACK A 1899 283 A A 1899 283 B 1 Group Block As...

Страница 34: ...How to Distinguish between the Old and New Stationary Barrels How to Distinguish the Old and New 1 Group Block Assy 1st Moving Frame ...

Страница 35: ...How to Distinguish between the Old and New Zoom Cam Barrels SOLUTION All old parts can t be supplied RIVISION HISTORY REV QTY DATE MEMO 2017 02 16 The whole revision ...

Отзывы: