1-5 (E)
DWT-B30
1-5. Item List in Test Mode
The item list in the test mode used for operation confirmation is described below. To enter each item,
hold down the
[SET]
button. The setting of each item can be switched using
[+]
and
[_]
buttons. There
are items in which the change in setting brings a violation of the law. For the item whose change is
prohibited, therefore, do not change the setting. Turn on the power again when you changed the setting
incorrectly. The change in setting may be able to be recovered.
Entering the test mode
1. Turn on the power of this unit.
2. Move a menu to VERSION.
3. Hold down the
[SET]
button for two seconds or more.
4. Press
the
[+]
,
[_]
, and
[+]
buttons sequentially.
5. Lastly, hold down the
[_]
button for two seconds or more.
Exiting the test mode
1. Turn off the power of this unit.
Item
Change
Function
MAIN CPU VER-
SION
_
Displays the firmware version of CPU (IC402) on the DPR-396 board.
FPGA VERSION
_
Displays the firmware version of FPGA (IC201) on the DPR-396 board.
REMOTE VERSION
_
Displays the firmware version of remote CPU (IC2000) on the RM-215 board.
CH PLAN VERSION
_
Displays the version of the channel plan built in EEPROM (IC813) on the
TX-172 board.
SERIAL NUMBER
_
Displays the serial number of this unit.
DESTINATION
Prohibited
Sets the destination of the RF circuit. Change is prohibited.
Not used for maintenance service.
RANGE0
Prohibition
of numerical
change
Changes the GAIN of the amplifier circuit of the RF circuit per frequency. The
value cannot be changed. In the service, the transmission frequency can be
changed by moving the screen to B (C), B (L) and B (H) used for the setting
of frequency during the measurement of RF.
RANGE1
RANGE2
RANGE3
RANGE4
TX DATA WRITE
Prohibited
The changed status of the TX-172 board is written in EEPROM (IC813).
Notice that the status cannot be recovered when it is written incorrectly.
Change is prohibited. Not used for maintenance service.
REMOTE MODE
Changeable
The remote mode can be changed. Not used for maintenance service.
REMOTE FREQ
Changeable
CH used for pairing can be changed. Not used for maintenance service.
INTERNAL MAC
_
Displays the remote control ID of this unit.
PAIRING MAC
_
Displays the remote control ID of a pairing partner.
CPU UPDATE
Prohibited
This is used for design and investigation. Not used for maintenance service.
ADC RESET
Changeable
This is used for design and investigation. Not used for maintenance service.
FREQ SET
Changeable
This is used for design and investigation. Not used for maintenance service.
ADC MODE
Prohibited
This is used for design and investigation. Not used for maintenance service.
IQ DAC CONTROL
Changeable
IQ DAC (IC300) on the DPR-396 board can be put into the SLEEP state.
In the SLEEP state, a non-modulated signal is output from the RF circuit.
Used during RF frequency measurement.
QMOD CONTROL
Changeable
This is used for design and investigation. Not used for maintenance service.
OEL ALL LIGHT
Changeable
Lights up all dots of the organic EL display.
All lights during ALL LIGHT setting.
FREQ 6MHz JUMP
Changeable
The transmit frequency of the RF circuit can be changed in units of 6 MHz.
Not used for maintenance service.
Содержание DWT-B30
Страница 4: ......
Страница 32: ......
Страница 48: ......
Страница 51: ...5 3 E DWT B30 4 Click the DOWNLOAD button 5 Click the Run button 6 Click Download and install this feature ...
Страница 65: ...5 17 E DWT B30 5 When the installation is completed click the Close button The installation has been completed ...
Страница 72: ...5 24 E DWT B30 5 Restart this unit 6 Click Troubleshoot 7 Click Advanced options 8 Click Startup Settings ...
Страница 95: ...i DWT B30 Revision History Date History Contents 2019 12 1st Edition 9 932 731 01 ...