7-2
DVP-NS15/NS51P/NS43P/NS53P/K56P
A
7-2.
ADJUSTMENT OF VIDEO SYSTEM
(DVP-NS15)
1.
Checking Scart Video Output Level (Video Mode)
<Purpose>
Checking Video Level the NTSC/PAL standard, and if not correct, the
brightness will be too large or small.
Mode
HLX-504 play back
Signal
Color bars 100%
Test point
VIDEO OUT (19p)
connector (75 W terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p
Adjusting method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2) Confirm that the Y level is 1.0 ± 0.08 Vp-p.
Fig. 7-2.
2.
Checking Scart S Video Output S-Y
(S-Video Mode)
<Purpose>
Check S-terminal video output. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with a S-terminal
cable.
Mode
HLX-504 play back
Signal
Color bars 100%
Test point
S VIDEO OUT (S-Y) (19p)
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.08 Vp-p
Checking method:
1)
In the Video Signal menu “1” Color Bar 100% play back.
2)
Confirm that the S-Y level is 1.0 ± 0.08 Vp-p.
Fig. 7-3.
3.
Checking Scart S Video Output S-C
(S-Video Mode)
<Purpose>
This checks whether the S-C satisfies the NTSC/PAL standard. If it is
not correct, the colors will be too dark or light.
Mode
HLX-504 play back
Signal
Color bars 100%
Test point
S VIDEO OUT (S-C) (15p)
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
A = 286 ± 50 mVp-p (NTSC)
A = 300 ± 50 mVp-p (PAL)
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the S-C burst is “A”.
Fig. 7-4.
4.
Checking RGB Output G (RGB Mode)
<Purpose>
This checks RGB video output G level. If it is incorrect, correct color
will not be remain some.
Mode
HLX-504 play back
Signal
Color bars
Test point
Green Out (11p) (75
Ω
terminated)
Instrument
Oscilloscope
Specification
A = 700 ± 70mVp-p
Checking method:
(1)
In the Video Signal menu “1” Color Bar 100% play back.
(2)
Confirm that the G level is 1.0 ± 0.08 Vp-p.
Fig. 7-5.
A
1.0 ± 0.08 Vp-p
1.0 ±0.08 Vp-p