Chapter 2
Location and Function of Parts
Chapter 2
Location and Function of Parts
2-9
2-1-3 Subsidiary Control Panel
Pull out the lower control panel to reveal the
subsidiary control panel.
1
EMPHASIS switch (DNW-A30/A30P only)
Set this to ON to apply emphasis to the analog
playback audio signal to convert the analog audio
signal to a digital audio signal.
2
CHARACTER switch
Select whether or not to superimpose text information
such as time code, menu settings, and alarm messages
on the video signal output from the COMPOSITE
VIDEO OUTPUT 3 (SUPER) connector.
ON: Superimposed text.
OFF: No superimposed text.
The factory default setting is ON.
3
DOLBY NR (noise reduction) switch (DNW-
A30/A30P only)
When using an oxide tape, switch the Dolby noise-
reduction system for analog audio on or off.
When using metal tape, the Dolby noise-reduction
system is automatically switched on, regardless of the
setting of this switch.
ON: Enable the Dolby noise-reduction system for
playback of an analog Betacam oxide tape.
OFF: Disable the Dolby noise-reduction system for
playback of an analog Betacam oxide tape.
The factory default setting is OFF.
4
PROCESS CONTROL switch
This selects the method of control of the internal
digital video processor.
REMOTE: Select this position to use an optional
BVR-50/50P Remote Control Unit for remote
control of the internal digital video processor.
MENU: Select this position to use setup menus to
change the settings for the internal digital video
processor.
LOCAL: Select this position to use the subsidiary
control panel to change the settings for the internal
digital video processor.
EMPHASIS CHARACTER DOLBY
NR
VIDEO
PROCESS
CONTROL
CHROMA
SET UP
Y/C DELAY
CHROMA PHASE SYNC
SC
KEY
INHIBIT
CAPSTAN
LOCK
ON
OFF
OFF ON
OFF ON
REMOTE
LOCAL
MENU
PRESET
MANUAL
PRESET
MANUAL
PRESET
MANUAL
PRESET
MANUAL
PRESET
MANUAL
SYSTEM PHASE
ON
OFF
2FD
8FD
4FD (625/50)
1
EMPHASIS switch (DNW-A30/A30P only)
0
SYNC knob
!¡
SC knob
2
CHARACTER switch
3
DOLBY NR switch (DNW-A30/A30P only)
5
VIDEO knob and PRESET/MANUAL switch
7
SET UP (DNW-A30/30)/BLACK LEVEL (DNW-A30P/30P) knob
and PRESET/MANUAL switch
6
CHROMA knob and PRESET/MANUAL switch
8
Y/C DELAY knob and PRESET/MANUAL switch
9
CHROMA PHASE knob and PRESET/MANUAL
switch
!™
KEY INHIBIT switch
!£
CAPSTAN LOCK switch
4
PROCESS
CONTROL switch
(DNW-A30)