5-13
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2-3.
INITIALIZATION OF 8, C PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the 8, C Page Data
Note1: If “Initializing the 8, C Page Data” is performed, all data
of the 8 page and C page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the 8, C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C page data
2) Serial No. input
3) Viewfinder system adjustments
4) LCD system adjustments
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0
±
0.1Vdc.
Adjusting page
8
Adjusting Address
00 to A3
Adjusting page
C
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C
Page Data”.
2. Modification of 8, C Page Data
If the 8, C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C
Page Data”).
Table. 5-1-6.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 18
19
1A to 2E
2F
30 to 3A
3B
3C to 49
4A
4B to 51
52
53 to 59
5A
5B to 79
7A
7B
7C
7D
7E
7F
80
81
82
83
84 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
08
00
46
01
02
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Содержание DCR-TRV40
Страница 60: ...Schematic diagram of the VC 283 board are not shown Pages from 4 33 to 4 70 are not shown ...
Страница 74: ...Mounted parts location of the VC 283 board is not shown Pages from 4 98 to 4 99 are not shown ...
Страница 75: ...5 1 DCR TRV40 TRV40E TRV50 TRV50E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 160: ...DCR TRV40 TRV40E TRV50 TRV50E 188 Sony EMCS Co 2003K1600 1 2003 11 Published by DI CS Strategy Div 9 929 951 31 ...
Страница 164: ... 4 DCR TRV40 TRV40E TRV50 TRV50E Sony EMCS Co 2002I1600 1 2002 9 Published by DI Customer Center 9 929 951 81 ...