5-8
DCR-TRV40/TRV40E/TRV50/TRV50E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B, 1E,
1F PAGE DATA
Note:
When reading or writing the 1B, 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select B, E or F page. The 1B, 1E
or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization of the
data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0
±
0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on
the LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C page data
4.
Initialization of E, F, 1E, 1F page data
Fig.5-1-6.
Battery terminal
Regulated power supply
Digital volt meter
Содержание DCR-TRV40
Страница 60: ...Schematic diagram of the VC 283 board are not shown Pages from 4 33 to 4 70 are not shown ...
Страница 74: ...Mounted parts location of the VC 283 board is not shown Pages from 4 98 to 4 99 are not shown ...
Страница 75: ...5 1 DCR TRV40 TRV40E TRV50 TRV50E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 160: ...DCR TRV40 TRV40E TRV50 TRV50E 188 Sony EMCS Co 2003K1600 1 2003 11 Published by DI CS Strategy Div 9 929 951 31 ...
Страница 164: ... 4 DCR TRV40 TRV40E TRV50 TRV50E Sony EMCS Co 2002I1600 1 2002 9 Published by DI Customer Center 9 929 951 81 ...