4-3. APC & AEQ Adjustment (VC-264 Board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
w;
of CN009 (RF MON) (Note 1)
Ext. trigger: Pin
qj
of CN009 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
“00”
Note 1:
Connect a 75
Ω
resistor between Pin
w;
and Pin
ql
(GND) of
CN009.
75
Ω
resistor (Parts code: 1-247-804-11)
Note 2:
The “AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
5
3
01
07
Set the data, and press PAUSE button.
6
3
02
Check that the data changes
from “07” to “00” in about 20
seconds after pressing PAUSE
button.
7
3
03
Check that the data is “00”.
(Note3)
8
Perform “Processing after
Completing Adjustments”.
Note 3:
If the data is other than “00”, adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note 4:
If this data is displayed twice successively, the machine is defective.
4-4. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
2
30
00
Set the data.
2
3
33
00
Set the data.
3
0
01
00
Set the data.
5. PLL fo & LPF fo Fine Adjustment (VC-264 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE button.
3
3
02
Check that the data changes to
“00” within 5 sec. (Note1).
4
3
03
Check that the data is “00”.
(Note2)
5
0
01
00
Set the data.
Note1:
If it is not satisfied, there are errors.
Note2:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Fig. 5-3-5.
Bit value of page: 3,
address: 03 data
bit 2 = 1 or bit 3 = 1
bit 4 = 1 or bit 5 = 1
bit 6 = 1
Error contents
PLL fo fine adjustment is defective
PLL fo adjustment is defective
LPF fo is defective
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание DCR-TRV30 - Digital Video Camera Recorder
Страница 95: ...DCR TRV30 TRV30E 4 61 4 62 CONTROL SWITCH LCD DRIVE CK 102 Uses unleaded solder ...
Страница 111: ...5 1 DCR TRV30 TRV30E SECTION 5 ADJUSTMENTS ...
Страница 188: ...Electrical parts list of the VC 264 board are not shown Pages 6 17 to 6 27 are not shown ...
Страница 191: ...DCR TRV30 TRV30E 224 Sony EMCS Co 2002F1600 1 2002 6 Published by DI Customer Center 9 929 886 31 ...