2-5
CCP-1100SF
2-7. Service mode
This mode facilitates adjustment of reel motor speed and
head azimuth.
Procedure :
Take out the cassette. Turn on the POWER switch while
pressing the REW and AUTO COPY buttons.
Keep pressing both buttons, and when the SHORT TAPE
indicator goes off after about 4 seconds, release the AUTO
COPY button. (At this time, do not release the REW button.)
Further after 2 seconds, make sure that the SHORT TAPE
indicator comes on again and the service mode is activated,
then release the REW button.
The following operation is available.
AUTO COPY : Same status as the COPY, with exception
that the bias dose not rise up. Accordingly,
the azimuth can easily be checked when
the record head is connected directly to
the playback amplifier.
COPY :
The COPY status is maintained, so that
the take up reel and plunger circuit can be
checked.
REW :
The REWIND status is maintained,
so that the supply reel circuit can be checked.
Note : In the COPY and REWIND modes, the shutoff and brake circuit do
not function. If a cassette tape is inserted, the reel motor can be
damaged at the end of tape. Therefor never insert a cassette tape.
[Test tape]
Type
Part No.
Frequency(Hz)
Level(dB)
P-4-L300
7-819-011-11
315
0
P-4-A063
7-819-914-11
6.3 k
_
10
P-4-A100-2
7-819-016-21
10 k
_
20
WS-48A
7-819-032-11
3 k
0
CQ-012C
8-909-708-02
Mirror, 12
u
Base
CQ-201B
8-909-708-41
Torque
Screw 1
Screw 2
Azimuth adjustment screw
Head board(P)
2-5. Head replacement
1.
Disconnect the lead wires of head at the solder part.
2.
Remove the head fixing screws. (For screw 1, only
loosen it.)
3.
Install a new head with screws 1and 2.
4.
After installation, adjust height and azimuth of the
head.
2-6. Cleaning mode
The set provides a cleaning mode and service mode to
facilitate the maintenance. Operate it in the procedure below.
Pinch roller
Capstan
Brush
Head
Erease head
The head block will come out so that the head and pinch
roller can easily be cleaned.
Procedure :
Take out the cassette. Turn on the POWER switch while
pressing the COPY button, and the head block will come
out in about 4 seconds.
The head block returns automatically after 5 minutes,
however, the cleaning mode cannot be reset unless other
than COPY button is pressed.