95
Specifying the Security Codes
You can authorize specific persons to set the menu to
Engineer mode, to operate this panel, and to adjust the
iris and master black by specifying a security code.
Locking Engineer mode with a security
code
1
Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press
[RCP Config]
to call the RCP
Config menu.
2
Set the menu to Engineer mode.
1)
Press
[Security]
on the RCP Config menu.
2)
Press and highlight
[Engineer Mode]
.
The
[Status]
,
[Menu Set]
, and
[Code No.]
buttons
are displayed.
3
Press
[Code No.]
.
The Security Code setting display appears.
4
Press
[Enable]
.
The Security Code input display now appears and
“Input New Code No.” is displayed.
5
Enter a security code and press
[Enter]
.
Use
[0]
to
[9]
to enter the security code (up to 8
digits).
Asterisks, each representing one digit of the
entered security code, are displayed in the upper
New Code No. box.
Press
[Back Space]
to cancel previous input one at
a time.
When you press
[Enter]
, the message “Input Again
to Confirm” is displayed.
6
Enter the security code again and press
[Enter]
.
Asterisks, each representing one digit of the
entered security code, are displayed in the lower
New Code No. box.
If you enter an incorrect security code, the message
“!!!Code No. NG!!!” is displayed.
When you enter the correct security code, the
Security Code setting display is resumed with
highlighted
[Enable]
and additional
[Code
Change]
.
After this setting, the Security Code input display
appears when you press
[Engineer Mode]
of the
Security menu.
Releasing the security code lock of
Engineer mode
1
When a security code for Engineer mode has been
set, operate in the same manner as step
1
through
step
4
in “Locking Engineer mode with a security
code.”
The Security Code input display appears.
2
Enter the security code and press
[Enter]
.
The security code lock is released.
Locking panel operations, iris/master
black adjustments menu with a security
code (Panel Active Lock)
1
Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press
[RCP Config]
to call the RCP
Config menu.
2
Set the menu to Engineer mode.
1)
Press
[Security]
on the RCP Config menu.
2)
Press and highlight
[Engineer Mode]
.
The
[Status]
,
[Menu Set]
, and
[Code No.]
buttons
are displayed.
3
Press
[Status]
.
The Security Status menu appears.
4
Press
B
to display the second page and press
[Enable]
.
Содержание CA-TX50
Страница 23: ......
Страница 24: ......
Страница 25: ...Sony Corporation Printed in Belguim ...
Страница 47: ......
Страница 67: ......
Страница 73: ......
Страница 101: ......
Страница 123: ... I 3 7 7 6 7 9 3 1 4 1 Sony Corporation Printed in Belgium ...
Страница 127: ......
Страница 139: ...Sony Corporation Printed in Belguim ...
Страница 153: ...67 Mounting on a Console The RCP D50 D51 can be mounted on a console as shown below ...
Страница 194: ...Printed in Belgium ...