![Sony BPU4800 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/sony/bpu4800/bpu4800_operating-instructions-manual_400229050.webp)
50
1) The portion in lower case letters in the above codes is one of the
following numbers.
pp: Number identifying the corresponding port.
81: HFR Data Record Port
82: Replay Port or HD Cut Out Port
B1: Transcode Port
2) Information in parentheses () indicates short messages for
superimposed display.
1C01pp
PORT x NO A7/A8 INPUT (P-x NO A7/A8)
Carrier cannot be detected on digital audio channel 7/channel 8
input of the displayed port.
210101
SLOT MX REC INHIBIT
(REC INHBIT)
Cannot record to memory due to a menu setting.
220201
SLOT MX FS LOCKED
(FS LOCKED)
The memory in the indicated slot is locked and cannot be
recorded.
220400
UNFORMATTED MEMORY BOARD DETECTION
An unformatted memory board was detected.
300100
POWER SUPPLY A INVALID INPUT VOLTAGE
The input voltage applied to power supply unit A is incorrect.
Check the applied power supply voltage.
300200
POWER SUPPLY B INVALID INPUT VOLTAGE
The input voltage applied to power supply unit B is incorrect.
Check the applied power supply voltage.
310100
POWER SUPPLY A MISCELLANEOUS DEFECT
An error was detected in power supply unit A.
310200
POWER SUPPLY B MISCELLANEOUS DEFECT
An error was detected in power supply unit B.
470100
RTC BATTERY LOW LEVEL
(RTC BATT LOW)
The lithium battery on the SY-422 board is low on power.
740200
ASYNCHRONOUS SHARE PLAY INTERFACE
SHARE PLAY operation malfunctioned because the phase
difference with the reference sync signal exceeded the permitted
range.
750191
SHARE PLAY1 INTERFACE DEFECTIVE
External Warning notification if the Share Play Primary is a valid
port but the link is down.
750192
SHARE PLAY2 INTERFACE DEFECTIVE
External Warning notification if the Share Play Secondary is a valid
port but the link is down.
90XX00
SYS1-APP SHARED MEM ACCESS FAIL 1, etc.
CAMERA APP and SYS1 communication is unstable.
AA0100
SYS1 FTP IF TASK ERROR
An error was detected in the FTP function of CPU (SYS1) on the
SY-422 board.
BB01pp
PORT x NMI COMMUNICATION ERROR
There was not response to the NMI command.
D204pp
PORT x DATA READ ERROR IN SHARE PLAY
An access error to target storage occurred during SHARE PLAY
execution.
D40201
SLOT MX AV READ ERROR2
A video playback error attributable to memory was detected.
D901pp
TRANSCODE PROC FAILED
An error occurred on the device during transcoding.
E10101
MEMORY FULL, NOT RECORDABLE
(M1 FULL)
The recording operation/command was terminated because there
was insufficient remaining recording capacity in memory.
Deletes files from memory.
E10201
MEMORY COND3 BAD, NOT RECORDABLE
(M1 COND3 BAD)
Cannot record because the swap space to replace bad memory
cells has been consumed in memory. The recording operation/
command was terminated.
E10301
MEMORY FUNCTION LIMIT
(M1 FUNC LIMIT)
The recording/playback operation was terminated due to memory
function limits related to recording and playback.
E10501
MEMORY MAXIMUM FILES, NOT RECORDABLE
(M1 MAX FILES)
The recording operation/command was terminated because the
number of files in memory has reached the upper limit.
Deletes files from memory.
E10601
MEMORY FILE SYSTEM STUFFED, NOT
RECORDABLE
(M1 FS STUFFED)
The recording operation/command was terminated because the
memory file system control limits have been reached.
Format the memory to use it for recording.
E202pp
PORT x FULL, STOP RECORDING
(P-x FULL STOP)
Recording was terminated for the indicated port because the
memory is full.
E401pp
PORT x NMI LINK RESOURCE LACK
An error was detected relating to the control from PRCM.
Code
1)
Indication
2)
Description