36
This setting is valid only when [TCG Source] is set to
“Internal-Preset” and the frame frequency is 29.97 Hz.
Timer Select
Selects the time data to display.
• TC
• UB
• TM1
• TM2
Timer Set
Displays the time counter.
To change the counter, enter a value and click the [Set]
button. Clicking the [Reset] button resets the counter.
Displayed only when [Timer Select] is set to TC, UB, or TM1.
Audio
CAM Input Select
Selects the input signal from the camera to record on the
audio file track.
• Off: Do not use the input signal from the camera.
• CAM Analog: Record the analog signal from the camera.
• CAM A/E: Record the AES/EBU signal from the camera.
• CAM A/E: Record the analog signal and
AES/EBU signal from the camera.
AES/EBU Input Mode
Selects whether to pass the input AES/EBU signal through
the sampling rate converter when recording.
• Auto: Use the converter. In this mode, there are no
limitations on the input signal.
• Vlock: Bypass the converter. In this mode, the input signal
must be 48 kHz and be locked to the video signal. Noise
may occur if this condition is not satisfied.
Internal Audio SG
Selects the type of signal to output from the internal signal
generator.
• Off: No output
• Silence: Silent signal
• 1kHz: 1 kHz sine wave
Note
Note