48
The message window closes automatically when the
process ends.
When files cannot be restored using salvage
If files cannot be restored even by performing a salvage, the
internal memory cannot be used in this condition. Formatting
memory will enable you to use it again.
1
If memory for which recording did not end normally
is detected, a warning message appears on the web
menu screen and a confirmation message appears
prompting you to salvage or format memory.
2
Select [FS Format] on the Storage screen of the web
menu.
The format process begins and a “Please wait.” message
appears.
The message window closes automatically when the
process ends.
If [Rec Inhi] is set to “On” on the [Setup] tab of the System
screen of the web menu, change the setting to “Off.”
Error Messages
Error messages displayed on monitor
When an error is detected in the unit or video camera, the
following messages may be displayed on the video output of
the SLOT3 LIVE monitor.
Display the menu or status screen to view messages.
Error messages displayed in web menu
If the unit ceases to operate correctly due to malfunction or
an internal system error, the SYSTEM indicator on the front
panel starts flashing yellow or red, and an error message
appears on the web menu screen.
After an error message appears, resolve the cause of the
error based on the error message and then turn the unit back
on. If the error message appears again when the unit is
turned on, contact your Sony representative.
Note
Note
Error message
Meaning
TEMP WARNING
Internal temperature error.
PLD NG
Internal PLD error.
PLEASE CONFIRM CHU
MODE ON CSA
The CSA camera head setting
does not match the connected
camera head.
PLEASE CONFIRM CHU
MODE ON BPU
The BPU camera head setting
does not match the connected
camera head.
PLEASE UPDATE CSA
SOFTWARE
The BPU and CSA software
versions do not match.
Error message
Meaning
Code
1)
Indication
Description
14xx00
PS FAN1 TROUBLE, etc.
A malfunction of cooling fan motor was detected. For details, refer
to the Maintenance Manual.
260100
POWER SUPPLY A UNIT TROUBLE
A failure was detected in power supply unit A.
260200
POWER SUPPLY B UNIT TROUBLE
A failure was detected in power supply unit B.
960100
CALENDAR CLOCK ERROR
An internal calendar clock error was detected.
B3xx00
B3xxpp
B3xxii
B33Ess
SY CPLD2 INITIAL ERROR, etc.
An error was detected at the device initialization stage. For details,
refer to the Maintenance Manual.
B80100
SYS1-SYS2 NO COMMUNICATION ERROR
An error occurred in communications with the two CPUS (SYS1,
SYS2) on the SY-422 board.
B80300
SYS1-NW NO COMMUNICATION ERROR
An error occurred in communications with the CPU (SYS1) on the
SY-422 board and the CPU (NW) on the CPU-453 board.
B90100
SYS1 INTERNAL ERROR
A software task error in SYS1 CPU was detected. For details, refer
to the Maintenance Manual.
BCxx00
SYS1-APP NO COMMUNICATION ERROR 1, etc.
An error occurred in CAMERA APP and SYS1 communications.
D103pp
PORT x ENC PROC ERROR
An error occurred during encoding. For details, refer to the
Maintenance Manual.
D2xxpp
PORT x DEC PROC ERROR, etc.
An error occurred during decoding. For details, refer to the
Maintenance Manual.
D3xx01
SLOT Mx AV WRITE ERROR1, etc.
An error occurred while writing to memory. For details, refer to the
Maintenance Manual.
D4xx01
SLOT Mx AV READ ERROR1, etc.
An error occurred while reading from memory. For details, refer to
the Maintenance Manual.