WARNING

To prevent fire or shock hazard, do not expose the unit to
rain or moisture.
To avoid electrical shock, do not open the cabinet.  Refer
servicing to qualified personnel only.

VORSICHT

Um Feuergefahr und die Gefahr eines elektrischen Schlages
zu vermeiden, darf das Gerät weder Regen noch
Feuchtigkeit ausgesetzt werden.
Um einen elektrischen Schlag zu vermeiden, darf das
Gehäuse nicht geöffnet werden.  Überlassen Sie
Wartungsarbeiten stets nur qualifiziertem Fachpersonal.

For the customers in the USA
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment.  This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.  Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of
FCC Rules.

WARNING:  THIS WARNING IS APPLICABLE FOR USA
ONLY.
If used in USA, use the UL LISTED power cord specified
below.
DO NOT USE ANY OTHER POWER CORD.

Plug Cap

Parallel blade with ground pin
(NEMA 5-15P Configuration)

Cord

Type SJT, three 16 or 18 AWG wires

Length

Less than 2.5 m (8 ft. 3 in.)

Rating

Minimum 10 A, 125 V

Using this unit at a voltage other than 120V may require the
use of a different line cord or attachment plug, or both.  To
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.

For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio).

Pour les clients européens
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE)  émises par la Commission de la Communauté
Européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN60950: Sécurité des produits
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère),
E3 (urbain extérieur) et E4 (environnement EMC contrôlé ex.
studio de télévision).

Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt
sowohl die EMV-Direktive (89/336/EEC) als auch die
Direktive Niederspannung (73/23/EEC) der EG-Kommission.
Die Erfüllung dieser Direktiven bedeutet Konformität für die
folgenden Europäischen Normen:
• EN60950: Produktsicherheit
• EN55103-1: Elektromagnetische Interferenz (Emission)
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter folgenden
elektromagnetischen Bedingungen ausgelegt:
E1 (Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien) und
E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio).

WARNING

This unit has no power switch.
When installing the unit, incorporate a readily accessible
disconnect device in the fixed wiring, or connect the power
cord to socket-outlet which must be provided near the unit
and easily accessible.
If a fault should occur during operation of the unit, operate
the disconnect device to switch the power supply off, or
disconnect the power cord.

WARNUNG

Dieses Gerät hat keinen Netzschalter.
Beim Einbau des Geräts ist daher im Festkabel ein leicht
zugänglicher Unterbrecher einzufügen, oder das Netzkabel
muß mit in der Nähe des Geräts befindlichen, leicht
zugänglichen Wandsteckdose verbunden werden.
Wenn während des Betriebs eine Funktionsstörung auftritt,
ist der Unterbrecher zu betätigen bzw. das Netzkabel
abzuziehen, damit die Stromversorgung zum Gerät
unterbrochen wird.

AVERTISSEMENT

Cet appareil n’a pas d’interrupteur d’alimentation.
Quand vous installez l’appareil, branchez un interrupteur
d’alimentation facile d’accès sur le câble fixe ou raccordez le
cordon d’alimentation à une prise proche de l’appareil et
facile d’accès.
En cas de problème en cours d’utilisation, déconnectez
l’appareil par l’interrupteur d’alimentation ou débranchez le
cordon d’alimentation.

WARNING
THIS APPARATUS MUST BE EARTHED.

WARNUNG
DIESES GERÄT MUSS GEERDET WERDEN.

AVERTISSEMENT
CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE.

Содержание BKS-R1617

Страница 1: ...OPERATION MANUAL English 1st Edition Revised 2 MULTI DISPLAY CONTROL UNIT BKS R1617 R1621 ...

Страница 2: ... urban outdoors and E4 controlled EMC environment ex TV studio Pour les clients européens Ce produit portant la marque CE est conforme à la fois à la Directive sur la compatibilité électromagnétique EMC 89 336 CEE et à la Directive sur les basses tensions 73 23 CEE émises par la Commission de la Communauté Européenne La conformité à ces directives implique la conformité aux normes européennes suiv...

Страница 3: ... of Multiple Control Units 8 Route Function 8 Phantom Function 9 VTR Control 9 Monitor Function 10 Level Control 10 Four Destination Control 10 Locations and Functions of Parts 11 Preparations 14 Settings on the Control Terminal 14 Preparations 14 Settings by Using the Buttons Setup Function 16 Operations 18 Error Messages 19 Specifications 20 ...

Страница 4: ...anel can be used as source select buttons or destination select buttons Your setting on the control terminal defines their functions The defined function for a button is indicated by the color green for source and amber for destination Displaying a source or destination name on each button The source and destination name defined with the control terminal can be shown on a key label on a button You...

Страница 5: ...nd 240 V AC without voltage adaptation Example of Setting the Select Button Functions The select buttons can be used as either source select buttons or destination select buttons The control terminal or the setup function of this unit allows you to define the function of each button The settings are made for each button For details on making settings on the control terminal refer to the Installati...

Страница 6: ...ontrol terminal Computer with the BZR 2000 installed Primary station Level 1 Video Source VTR Destination VTR S BUS line Signal RS 232C T Bridge 75 ohm terminator3 Matrix level Video Video Audio Time code DVS A3232 Audio Routing Switcher S 2 Routing switcher HDS X3700 Video Routing Switcher P 1 DVS V3232M Video Routing Switcher S 2 DVS TC3232 Time Code Routing Switcher S 2 Secondary station Video ...

Страница 7: ...ource Destination LEVEL 1 IN 11 OUT 3 LEVEL 2 IN 14 OUT 3 LEVEL 3 IN 16 OUT 3 When the break away function is used single level mode Source VTR Video Level 1 Audio channels 1 2 Level 2 Audio channels 3 4 Level 3 Video routing switcher Audio routing switcher Destination VTR Source VTR Video Level 1 Audio channels 1 2 Level 2 Audio channels 3 4 Level 3 Video routing switcher Audio routing switcher D...

Страница 8: ...spoint is switched on switcher A in the figure below normally IN5 appears as the source name If the route function has been set the source name selected on switcher A appears To activate the route function set the destination of switcher A destination and source of switcher B and level In the case of the figure below set OUT1 OUT2 IN5 10000000 When you use the route function switching is possible ...

Страница 9: ...nector number of the destination selected when phantom switching For example if the destination is OUT005 the connector number of the destination is 015 and the offset value is 2 2 the destination 017 is switched To execute the destination offset local phantom first select and check the destination Examples of this Phantom are given below Example 1 Assign a source audio source AUD007 for example o...

Страница 10: ...You can assign levels to source destination select buttons and use as the LEVEL select buttons Four Destination Control You can divide source destination select buttons to four blocks and assign destinations to each blocks Conventional monitor system Example of source offset system Source offset Monitor display panel Standard system D1 signal HD to D1 Down conversion HD signal Monitor display pane...

Страница 11: ...the assignment of a source select button While holding down this button press a source select button and the source name displayed in the preset display window is assigned to the pressed button Front panel Rear panel 4 Preset display window BKS R1617 BKS R1621 Front panel Rear panel 5 PROT button lamp 4 Preset display window 6 LOCK CHOP button lamp 3 Display window 7 Source destination select butt...

Страница 12: ...that the lamp goes out Note If the protection has been set to ON AIR mode at the control terminal switching is enabled independently of the protection setting Normally set the protection to NORMAL mode 6 LOCK CHOP button lamp This button has two functions lock function and chop function Lock function Press and light this button in red and the buttons on the front panel other than this button are d...

Страница 13: ...g to the pressed button is selected The pressed button lights in bright amber to show the selected destination 8 SELECTOR knob When you turn the knob with the DEST lamp not lit source names appear in sequence in the preset display window When the DEST lamp is lit a destination name appears While you turn the knob with the ASSIGN button held down the type name appears in sequence in the preset disp...

Страница 14: ...tching signals with this unit the following preparations should be made on the control terminal connected to the primary station of the S BUS data link For details on making the settings refer to the installation manual supplied with the routing switcher 1 Set the type of the input and output connector name to either the type name and number mode or the description name mode 2 Set the type names o...

Страница 15: ...ls these are called key labels and attach them on the source destination select buttons Then you can see at a glance what functions you have assigned to each button Key label guide For a large button 14 14 mm For a small button 9 5 9 5 mm Making a key label 1 Copy the key label guide shown below onto a sheet of OHP paper 2 Write the name on the copied paper 3 Cut the paper to the button size as sh...

Страница 16: ... as described below Initializing the settings While holding down buttons 1 and 2 turn the power on The following items are set to the factory set conditions 1 Status display mode 2 Single use mode 3 Phantom partial protect mode Note Press buttons until the lamp check on the panel is completed Setting single use mode While holding down buttons 5 and 8 turn the power on Use this mode when this unit ...

Страница 17: ...ns 9 10 and 11 turn the power on If one of the destinations set on a phantom is protected switching of the crosspoints including the protected destination is prohibited but the other crosspoints are switched Entering station number setting mode While holding down buttons 1 2 3 and 4 turn the power on The station number can be set with binariy coding using buttons 1 through 8 Resetting the software...

Страница 18: ...ils on making the settings refer to the Installation Manual supplied with the routing switcher Lighting status of the source destination select buttons The source select buttons are normally lit in dim green and the destination select buttons are lit in dim amber When you press a button for selecting a signal to be monitored the pressed source or destination button lights in bright green Yes No Ye...

Страница 19: ...set as secret cannot be selected on a unit other than the primary station ComE Communication error of the S BUS data This may occur when the communication period is too long link The primary station may be turned off or the remote cable may be disconnected Prot The destination is protected The protected destination cannot be switched In the preset display window ID of the station which has set the...

Страница 20: ... 100 to 240 V AC for the other countries 50 60 Hz Current consumption BKS R1617 0 35 A BKS R1621 0 28 A Peak inrush current BKS R1617 1 Power ON current probe method 24 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 8 A 230 V Peak inrush current BKS R1621 1 Power ON current probe method 20 A 240 V 2 Hot switching inrush current measured in accordance...

Страница 21: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 22: ...Sony Corporation Communication System Solutions Network Company BKS R1617 R1621 WW 3 203 873 23 1 2000 09 1999 ...

Отзывы: