2-47
FVS-1000 MMP1
S1700
S1701
S1500
S1501
A
B
C
D
E
1
2
3
4
5
DSP-81 BOARD (A SIDE)
2-11. Function of Switches/LEDs on the Board
2-11-7. DSP-81 Board
Switches
n
Do not change the setting of the switch described as “Factory use only”
Ref.No.
Address
Name
Function
Factory setting
S1700
(E-4)
HIB Enable/Disable select
S1700-1 : HIB Enable/Disable
OFF: Enable
*
1
ON: Disable
*
2
S1700-2 : Scan structure
OFF: Progressive (8:4:4 V)
ON: Interlace
S1700-3 : Line Standard
OFF: 525
ON: 625
S1700-4 : Factory use only
S1700-5 : Factory use only
S1700-6 : Factory use only
S1700-7 : TSG enable
OFF: Main(video from DCP)
ON: TSG
S1700-8 : TSG enable
(This bit activated on S1700-7 is ON)
OFF: Fixed(flat field) signal
ON: H or V signal
ON