KD-65X8000C(CH)
9
SELF DIAGNOSIS FUNCTION
[SELF DIAGNOSTIC SCREEN DISPLAY]
[SELF DIAGNOSTIC SCREEN DISPLAY]
•
Panel Operation Time is recorded every
30 min, but Total Operation Time is recorded every 1 hr.
Therefore, the panel op. time might become larger than
the total op. time.
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
SELF CHECK
<<
002 MAIN_POWER 000000000000 000000000000 000000000000 000
003 DC_ALERT 000000000000 000000000000 000000000000 000
003 AUD_ERR 150101000018 150101000018 150101000018 003
003 HDMI_EQ 150101000123 150101000045 150101000045 003
003 TU_DEMOD 150101000218 150101000223 150101000105 003
004 LD_ERR 000000000000 000000000000 000000000000 000
004 BCM_ERR 000000000000 000000000000 000000000000 000
005 TCON_ERR 150101000504 000000000000 000000000000 001
005 P_ID_ERR 000000000000 000000000000 000000000000 000
006 BACKLIGHT ERR 000000000000 000000000000 000000000000 000
007 TEMP_ERR 150101000200 150101000002 000000000000 002
007 4KBE_ERR 000000000000 000000000000 000000000000 000
008 SW_ERR 000000000000 000000000000 000000000000 000
Back
00005 00414 00002
[Home]Exit
Smart Core Red
LED blinking count
Error item
Naming
Error count
Total Operation Time [hr]
– Boot Count – Panel Operation Time [hr]
Error
timestamp for
last recorded
error
Error
timestamp for
second last
recorded error
Error
timestamp for
3rd last
recorded error
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen.
After you have completed the repairs, clear the result display to “0”.
Clearing the Self Check Diagnostic List
Panel operation time :
Press the Channel 7 => Channel 0 .
To exit the Self Diagnostic screen...
If you want to finish service mode app, do AC OFF/ON
→*Service mode app is disable perfectly if you want to move home menu, push <HOME>button
→*Service mode app do background(not disable perfectly)
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes
out” that cannot be confirmed, it is possible to bring up past occurrences of failure for
confirmation on the screen.
In standby mode, press buttons on the remote commander sequentially in rapid succession
as shown below:
NOTE:
This model does not have the function to clear the error history of self-diagnostic screen
by remote such as press the Channel 8 => Channel 0.
" These error item
does not work."