Power Supply and Jumper Cables (optional)
1.
Install the power supply (POS-77) according to the manufacturer’s instructions.
2.
Connect the jumper cables to the power supply’s (POS-77) output terminals. Red (POS-88) to
the positive output terminal and black (POS-89) to the negative output terminal.
3.
Connect the banana plugs of the red and black jumper cables to the battery eliminator’s
(POS-52) red and black connectors.
4.
Set the output of the Power Supply as follows:
•
Voltage: 3.8Vdc
•
Current: 2.0 amps
5
Lead-Free Electrical Repair
This product is manufactured with lead-free solder and lead-free components. During electrical
repair, it is critical to make sure that no lead is introduced into the product. For this reason,
certain repair materials and equipment must be designated as lead-free and labelled accordingly.
A lead-free work area must be setup that is completely separated from work areas that are used to
make leaded repairs. The lead-free work area must also be clearly labelled as shown in the figure
below. Certain items must be designated for lead-free work only. Some of the items that need to
be clearly labelled in this way are listed in the table below. Note that any item that contacts the
solder must be labelled and used for lead-free work only.
Soldering Tips
Wicking Tape
Tip Cleaner (steel wool)
Solder
Tip Tinner
Soldering Iron