Страница 1: ...Ultrasonic Flow Sensor SONOFLOW IL 52 V2 0 User Documentation Including Technical Data Sheet Operating Manual Certificates...

Страница 2: ...This page has been deliberately left empty...

Страница 3: ...in areas with rigorous hygiene requirements the sensor is suitable for circulation cleaning and steam sterilization General data SONOFLOW IL 52 3 V2 0 Ultrasonic Flow Sensor for Liquids Order No IL 5...

Страница 4: ...on FFKM Operating voltage 12 30 VDC ripple max 10 protection against reverse polarity external fuse if required min 200 mA Current consumption Maximum 50 mA with open current frequency and switching o...

Страница 5: ...e interface is not used it does not necessarily has to be connected the two pins A and B can remain open RS485 Bus operation The sensor supports bus operation with max 12 subscribers The default addre...

Страница 6: ...temperature 0 70 C Storage temperature 20 70 C Directives and standards EMC directive 2014 30 EU RoHS 2011 65 EU exception III 7cI IV 15 Acoustic emission IEC 61157 Maintenance Maintenance free Scope...

Страница 7: ...le connector at the sensor Female connector at the cable M12 connecting cable Pin Color Connection Assignment 1 White Ground 2 Brown Operating voltage 12 30 VDC 3 Green Current output 0 4 20 mA 4 Yell...

Страница 8: ...ded holes M5 depth 10 Drawings are not to scale Dimensions in mm unless otherwise specified Information is subject to change without notice HEADQUARTERS GERMANY SONOTEC GmbH Nauendorfer Str 2 06112 Ha...

Страница 9: ...Ultrasonic Flow Sensor Type SONOFLOW IL 52 V2 0 Operating Manual...

Страница 10: ...SONOTEC Ultraschallsensorik Halle GmbH All rights reserved Revision 1 0 Date 2018 10 26 Information is subject to change without notice...

Страница 11: ...ing 10 3 4 Requirements for Liquid 10 3 5 Parameterization calibration and readout of measuring values Accessories 10 4 Installation and commissioning 11 4 1 Attaching the Sensor SONOFLOW IL 52 V2 0 1...

Страница 12: ...SONOFLOW IL 52 V2 0 Operating Manual 4 Revision 1 0 Date 2018 10 26 This page has been deliberately left empty...

Страница 13: ...all the instructions to ensure safe operation of the SONOFLOW IL 52 V2 0 1 2 Symbols used Hazards or special information is indicated in the following ways Warns of imminent threat of danger with very...

Страница 14: ...SONOFLOW IL 52 V2 0 Operating Manual 6 Revision 1 0 Date 2018 10 26 This page has been deliberately left empty...

Страница 15: ...chnical Data Sheet Make sure to read all safety regulations NEVER CHANGE SETTINGS of the sensor before you have saved all parameters with the help of SONOFLOW Monitor Ignoring the safety instructions...

Страница 16: ...temperatures and voltage range must be met unconditionally Values are not allowed to exceed or to fall below the specified limits not even temporarily The sensor may only be exposed to a minimal risk...

Страница 17: ...including to third parties caused by improper handling of the sensors 3 2 Construction The SONOFLOW IL 52 V2 0 consists of two ultrasonic transducers appropriate control electronics and evaluation el...

Страница 18: ...le Frequency output for flow rate 0 to 20 kHz 5 V digital RS485 interface bus capable Switching output configurable as PNP NPN Push Pull 0 to 30 V Digital input MODBus on request Please find the descr...

Страница 19: ...rations can affect sensor functions Ensure that the mounting or the tubes lines do not transmit vibrations to the sensor Recommended is an installation position with a flow direction against the force...

Страница 20: ...mA Range 4 20 mA 0 20 mA Limit 20 mA 20 mA Flow min 0 ml min 4 mA 0 3 000 ml min Flow max 3 000 ml min 20 mA 0 3 000 ml min Measuring Error 2 mA 0 22 mA Device Fault 0 mA 0 22 mA Table 3 Default setti...

Страница 21: ...ulse volume Pulse volume in ml Threshold Flow On 1500 ml min 0 3 000 ml min Threshold Flow Off 1200 ml min 0 3 000 ml min Totalized volume Enable volume calculation Enable negative volume Table 5 Defa...

Страница 22: ...gs 14 Revision 1 0 Date 2018 10 26 5 5 Digital input Parameter Default setting Further options via SONOFLOW Monitor Configuration Flow Zero Adjust OFF Reset Volume Restart Option to Zero adjust Deacti...

Страница 23: ...send via the configured outputs If there is visible damage take the sensor out of operation immediately 6 2 Cleaning and Disinfection Incorrect cleaning of the sensors SONOFLOW IL 52 V2 0 and its com...

Страница 24: ...sensor has self test routines and sets defined output signals if an error is detected The error output can be customized Description Remedy Measuring Error e g gas in the sensor Try to remove the gas...

Страница 25: ...range a separate disposal for electronic equipment It has to be handled according to specific processes e g concerning the batteries or circuit boards to ensure a safe environmentally friendly recycli...

Страница 26: ...UFACTURER SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Str 2 06112 Halle Saale Germany Tel 49 0 345 133 17 0 sonotec sonotec de www sonotec de USA CONTACT DETAILS SONOTEC US Inc 190 Blydenburgh...

Страница 27: ......

Страница 28: ......