Connector  (non-Power Feed)

 - 

Shown with 23CxxE201 (Fig. 10)

1. Drill a 3/4" hole where the Connector (B) is to be installed.

2. Loosen set screws (A) with included Allen key (F) and remove Connector (B) from mounting bracket (C).

3. Insert toggle anchor (D) through hole in wall and tighten screw (E) until it is secured in place.

4. Cap or trim exposed ends of Connector wires and place inside Connector (B).

5. Place connector (B) on mounting bracket (C) and secure by tightening set screws (A) with included Allen key.

Connector Installation (cont.)

Power Feed Connector with Remote Driver 

 - 

Shown with 23CxxE201 (Fig. 8-9)

1. Shut off power to the branch circuit conductors.

2. The LED driver (A) must be installed in a remote and accessible location near the fixture in accordance with local 

electrical code (Fig. 9). Make appropriate electrical connections using wire nuts:

a. Connect the LED driver's (A) live wire to the live branch circuit conductor.

b. Connect the LED driver’s neutral wire to the neutral branch circuit conductor.

c. Connect the LED driver’s positive (+) output wire to the required length of red wire (not included) to reach the 

Connector (B).

d. Connect the LED Driver's negative (-) output wire to the required length of black wire (not included) to reach the 

Connector.

3. Drill a 3/4" hole (J) in the wall where the Connector (B) is to be installed. 

 

4. Using included Allen key (K), loosen set screws (H) and remove Connector (B) from mounting bracket (C).

5. Pull low voltage wires (F) through off-center hole (G) in mounting bracket (C).

6. Make appropriate electrical connections using wire nuts:

a. Connect the positive (red) low voltage wire to the Connector red wire.

b. Connect the negative (black) low voltage wire to the Connector black wire.

c. Carefully place connections inside Connector (C).

7. Insert toggle anchor (D) through hole in wall (J) and tighten screw (E) until it is secured in place, making sure not to 

pinch the connector wires.

8. Place connector (B) on mounting bracket (C) and secure by tightening set screws (H) with included Allen key.

A

Fig. 9

Fig. 8

Fig. 10

Содержание purolinear 360

Страница 1: ...purolinear 360 assembly instructions...

Страница 2: ...CTIONNEMENT DU PRODUIT ET LES RISQUES Suitable for Damp Locations Convient aux Emplacements Humides Please read all included assembly instructions and warnings carefully before installation Contact Cu...

Страница 3: ...ted in their Connectors to shine in any direction The Connectors form a structural and electrical connection between the Luminaires and can be configured in many different ways Any Connector can be us...

Страница 4: ...om power feed Fig 3 July 7 2020 2020 SONNEMAN A Way of Light 3 of 7 System Layout Considerations To prevent electrical overload and avoid excessive voltage drop 1 Do not exceed 8ft total Luminaire len...

Страница 5: ...may be used as a power feed Fig 6 A B Fig 5 4 Configurations that violate any of the prior requirements must be split into two or more electrically isolated subsections each of which meets the requir...

Страница 6: ...iver s negative output wire to the black connector wire g Carefully place driver and connections in outlet box 3 Install cross bar C to outlet box using outlet box screws D 4 Using included Allen key...

Страница 7: ...ive wire to the live branch circuit conductor b Connect the LED driver s neutral wire to the neutral branch circuit conductor c Connect the LED driver s positive output wire to the required length of...

Страница 8: ...both connector ports while moving Connector B onto its mounting bracket If necessary adjust Connector B position to ensure Luminaire is fully inserted into both connector ports loosen the toggle anch...

Отзывы: