22
4 Network Discovery and Webserver
Configuration : Physical Settings
This page shows you the settings which are currently selected according to
the physical switches on the back panel of the unit.
Configuration
This option allows you to select whether to use the
options set by the physical controls on the unit,
or the options set up using this webserver. When
using the physical control settings many options on
the webpage will become grey to indicate that they
are not currently enforced.
Front Panel
This option allows you to lock or unlock the use of
the three front panel buttons; Source, Mode and
Restore.
Brightness Level
This option allows you to control the brightness
of the LEDs on the front panel of the unit, with 3
being the brightest.
Note:
You may have to refresh the web page in
order to be sure that you are seeing the most
current physical settings for this unit.
Power On Auto
When enabled, this option enforces certain
conditions on unit boot up. The Restore Mode
will be set to Automatic, the Auto Lock Mode will
be turned on and Source Indication will be set
to Output Signal. All other configurations will be
retained.
Note:
The settings affected by Power On Auto may
be reconfigured whilst the unit is running. They will
only return to the configuration stated above on
boot up. Power On Auto will be disabled when the
unit is reset to default configuration.
Fig 4-13: RB-SD1IP Screenshot of the Webserver Physical Settings Page