![Sonifex AVN-CU2-DANTE Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/sonifex/avn-cu2-dante/avn-cu2-dante_handbook_1321134078.webp)
72
7
System Menu
72
6
Embedded Web Server
Load Configuration from A File
This section is used to load stored pre-set files, this is useful when the unit
is being moved between locations with different setups. Configuration files
store the complete setup of the unit including the units network settings,
however network settings are only changed when the overwrite network
settings checkbox is selected.
A maximum of 8 pre-sets can be added to the unit, a pre-set is added by
clicking the Add button and selecting a local configuration file. A pre-set can
be removed by selecting it in the menu and clicking the Remove button. A
pre-set is loaded on the unit by selecting the pre-set in the menu and
pressing the Select button, if it is necessary to also load the network
settings that are present in the configuration file the overwrite network
settings checkbox can be selected. If you would like to maintain the current
network settings, uncheck this option and all other settings stored in the
selected pre-set will be applied.
When a pre-set is loaded the unit will automatically reboot to load the new
configuration settings. This takes approximately 25 seconds during which
time; a progress page will be shown. If the settings of the network port the
browser is connected to have changed, a new connection will need to be
made once the unit has restarted. Otherwise, the device information page
will be shown automatically.
Save System Log to A File
An internal log records system events and errors. The current log can be
retrieved from the device by clicking Save log.
If there have been no process crashes the current log is saved and is a single
text file. Otherwise multiple logs will be stored together in a ‘TAR’ archive
file. This archive can be sent to Sonifex to help you resolve any issues with
the unit.
Reboot or Factory Reset
The unit can be rebooted using the reboot button, a quick reboot can often
fix any issues with the unit, after rebooting the webpage should
automatically be reloaded. The factory reset button restores the unit to
factory settings, restoring the factory settings will also cause the unit to
reboot.
The pre-set configuration files previously uploaded to the unit will still be
available after a factory reset, this allows the unit to be quickly restored to
a known working state.