![Sonifex AVN-CU2-DANTE Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/sonifex/avn-cu2-dante/avn-cu2-dante_handbook_1321134073.webp)
67
Embedded Web Server
6
Input Mode (Physical GPI Only)
Momentary
When the input mode is set to Momentary, the input function is enabled
only whilst the input is active.
Latching
When the input mode is set to Latching, making the input active briefly will
toggle whether the input function is enabled or disabled.
vGPIO Source (Virtual GPI Only)
The vGPIO Source drop-down window allows the user to select a virtual
general-purpose output port from another device that is available on the
network and use that to set the state of the virtual input.
Available Events
This drop-down menu allows an event to be selected that can then be used
as an input to drive the state of another output, the list of options are as
follows.
Primary Link Down
Active when no connection is available via the primary network port on the
device.
Secondary Link Down
Active when no connection is available via the secondary network port on
the device.
AC Power Off (AVN-CU4 Only)
Active when the status of the AC port is in fault condition.
DC Power Off
Active when the status of the DC port is in fault condition.
POE1 Power Off
Active when the status of the primary PoE port is in fault condition.
POE2 Power Off
Active when the status of the secondary PoE port is in fault condition.
PTP Sync Lost
Active when the connection to the PTP master is lost.
On Air
n
Active when commentator position
n
is on air.
Cough
n
Active when commentator position
n
is in cough mode.
T/B
n l
Active when commentator position
n
is routed to talkback bus
l
.
Available Buttons
The Available Buttons drop-down menu allows the user to select which of
the available user buttons to setup, this provides 12 user buttons on the
AVN-CU2 variant and 24 user buttons on the AVN-CU4 variant.