6
Single-pole phase testing may not be sufficient
to determine whether the circuit is live. Perform
two-pole voltage test.
2.5 Circuit continuity test
Note!
The tested object must not be live.
Connect both probes to the tested object. A
sound signal, diode
Ω
on, and the
legend in-
dicate continuity of the circuit (R<600k
Ω
).
Notes:
During the circuit continuity measurement, the
voltage polarization at the L2 probe is negative!
2.6 Measurement of resistance
Note!
The tested object must not be live.
Press the
Ω
button for a short while and con-
nect both probes to the tested object. Read the re-
sult from the LCD.
Notes:
During the resistance measurement, the volt-
age polarization at the L2 probe is negative!