Sonance DSP 8-130 MKII SONAMP Скачать руководство пользователя страница 14

12

Delay

Parametric EQ

EQ On/Off

 

EQ Frequency Hz

 

EQ-Q

 

EQ Gain +/-dB

 

Delay is shown in Milliseconds, Feet and Meters. You can 
make an entry in any of the three fields and the other fields 
will be calculated automatically. 
The minimum delay is .01 milliseconds, the maximum delay 
is 12 milliseconds. 
This function is useful when compensating for distance 
between satellites and subwoofers for instance. 

All Sonance DSP amplifier models feature a 10 band 
parametric EQ. Adjustments made to the EQ will be displayed 
on the Output Frequency Response graph. We strongly 
suggest not adjusting the EQ without proper measurement 
equipment.

Turns each of the 10 parametric EQ filters on and off. 

Enter the center frequency (20Hz - 20kHz) for the filter to 
be adjusted.

This setting determines the width of the adjustment range. 
The lower the number the wider the bandwidth. The higher 
the number the narrower the bandwidth.

The level of each parametric adjustment can be set +/-12dB. 
Careful adjustment of the EQ Gain is necessary to prevent 
damage to the speakers. Always increase the level as little 
as possible. The first choice should always be to reduce the 
output to achieve the target frequency response. 

Import Single Preset

   

Copy Preset    

1. Import speaker preset to a location on your computer.
  This can be accomplished by saving a DSP preset
  downloaded from Sonance website. 
2. Select the location you would like to store the new
  preset using the SELECT PRESET TO EDIT pull down menu.
  You can save the new preset in any of the open preset locations 
   or you can overwrite an existing preset you do not need. 
3. Press the green IMPORT button. 
4. From the pop-up menu choose local or internet. 
5. You will be directed to MY COMPUTER (WINDOWS) or  
  FINDER (MAC). 
6. Find & Select the new preset you would like to import (.eqs). 
7.  You will be directed to a screen that says Upload Successful. 
8. Press “Click Here To Go Back”.
9. The preset will now be saved in the location you selected.  
 

NOTE: PRESETS DOWNLOADED FROM INTERNET CAN  
TAKE UP TO 15 SECONDS TO DOWNLOAD.

From / To the blue pull down menus allow you to pull a 
preset from one location and assign it to another location. 
Press green copy button to activate.

Output Frequency Response

This graph reflects the changes made below.
The above EQ image shows EQ4 ON at 500Hz, the Q is set 
to 3 with a -6dB gain, creating a gradual dip in the lower 
midrange. 
EQ9 shows ON at 3000Hz, the Q is set to 10 with a -6dB 
gain, creating a sharp dip in the midrange. 
EQ10 shows ON at 10000Hz, the Q is set to 1 with a +4dB 
gain, creating a very gradual slope in the high frequencies. 

Содержание DSP 8-130 MKII SONAMP

Страница 1: ...DSP 8 130 MKII SONAMP MULTI CHANNEL POWER AMPLIFIER WITH INSTRUCTION MANUAL 06 14 17...

Страница 2: ...and Volume Level Controls 6 Protection Circuitry and LEDs 6 Rack Ear Installation and Shelf Mounting 6 Software V2 7 Network Connection Instructions 7 Homepage 7 Basic Setup Page 7 Advanced Setup Pag...

Страница 3: ...e amplifier use canned air or wipe the amplifier with a soft cloth Do not use solvents as they may damage the amplifier 12 Non use periods Unplug the amplifier s power cord from the outlet when the am...

Страница 4: ...e interventions av rera n cessaire si l appareil a t endommag pour quelque raison que ce soit et par exemple si le c ble d alimentation secteur ou sa prise sont endommag s si du liquide a p n tr l int...

Страница 5: ...mp DSP 8 130 MKII box should contain 1 Quickstart guide 1 Sonamp DSP 8 130 MKII amplifier 1 IEC power cord 4 Feet 2 Rack ears Unpacking Save the carton and polystyrene inserts for future safe transpor...

Страница 6: ...g channels use the two outside connections on each connector The positive wire from the speaker should be on the left side connection and the negative connection should be on the right side Auto On Vo...

Страница 7: ...CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR S N T5AL 250VAC 2 100 AC 100 120V 60Hz CAUTION REPLACE FUSE ONLY WITH SAME TYPE AND RATING ATTENTION REMPLACER U...

Страница 8: ...r extremely low impedance the affected channel outputs automatically mute The output of the effected channel will remain muted until the fault has been corrected Only the effected channels output will...

Страница 9: ...he IP address of the Sonance DSP amplifier to configure SONARC Legend Toggle Pull down Menu Free Type Field Single Action Menu SONARC Homepage Setup Options Your SONARC Homepage will have two options...

Страница 10: ...T AND RIGHT CHANNELS ARE LINKED OUTPUT VOLUME IS LINKED TO TURN ON VOLUME IN BASIC SETUP ADVANCED SETUP PAGE GENERAL SETTINGS TAB Advanced Setup IP SETUP DHCP On Off To start click on the Advanced Set...

Страница 11: ...ep Mode options Each channel has an independent Sleep Mode setting The Sleep Mode is triggered by an audio sensing circuit on each channel of the amplifier Voltage Green In the Voltage Green Auto On m...

Страница 12: ...ments of 5dB This is a user entered field with a maximum of 15 characters Use these fields to describe the location of the speakers Allows each channel to be set for Stereo or Mono operation When Mono...

Страница 13: ...RC software includes a built in pink noise generator The pink noise signal can be used in conjunction with a real time analyzer to measure speakers You have the option of pink noise or test signals fe...

Страница 14: ...se Import Single Preset Copy Preset 1 Import speaker preset to a location on your computer This can be accomplished by saving a DSP preset downloaded from Sonance website 2 Select the location you wou...

Страница 15: ...k of damage to the loudspeakers Crossover LP Xover HP Xover Frequency Filter Type Limiter This setting turns the high and low pass crossovers ON and OFF In this field you can enter any frequency betwe...

Страница 16: ...riven 4 ohms sinewave 1 8 power 226 Watts all channels driven idle 35 Watts Sleep Mode 1 1 Watts Voltage or Audio Green 0 45 Watts Power Consumption 220V AC 8 ohms sinewave full power 1097 Watts all c...

Страница 17: ...eset Steps Step 1 Turn amplifier off Step 2 With light pressure adjust 1L Volume Control full counter clockwise Step 3 With light pressure adjust 1R Volume Control full clockwise Step 4 Power on ampli...

Страница 18: ...LTAGE NONE 6 8 seconds Always On AUTO ON SETTING SLEEP MODE OPTIONS TIME TO MUSIC ETHERNET VOLTAGE GREEN NONE 6 8 seconds Turn Off after 15 MIN without voltage AUTO ON SETTING SLEEP MODE OPTIONS TIME...

Страница 19: ...ALL NOT BE LIABLE FOR CONSEQUENTIAL INCIDENTAL ECONOMIC PROPERTY BODILY INJURY OR PERSONAL INJURY DAMAGES ARISING FROM THE PRODUCT ANY BREACH OF THIS WARRANTY OR OTHERWISE This warranty statement give...

Отзывы: