Sonance DSP 8-130 MKII SONAMP Скачать руководство пользователя страница 10

8

Output Settings / Output Volume

Identify Amplifier

Output Name

ID Amp Mode

Info

Output Volume

This is a user entered field with a maximum of 15 characters. 
Use these fields to describe the room or area the channel 
will be powering.

When the power switch is turned ON, the power button on 
the front of the amplifier will flash to indicate which amplifier 
you are programming. This will make the amplifier easy to 
identify in a multiple amplifier installation.

This is a user entered field with a maximum of 15 
characters. Use this area to name your MKII.

The basic setup is complete!

If you are using a control system to adjust the volume you 
can skip these two steps. 
1. Set the Output Volume for each channel pair. 
2. Set the Turn On Volume the same as the Output Volume.
  a.  It’s important to set the Turn On Volume the same in 
    case the amplifier power is shut off accidentally.
  b.  Front panel level controls overwrite these two settings.

NOTE: LEFT AND RIGHT CHANNELS ARE LINKED. OUTPUT 
VOLUME IS LINKED TO TURN ON VOLUME IN BASIC SETUP.

ADVANCED SETUP PAGE

GENERAL SETTINGS TAB

Advanced Setup 

IP SETUP 

DHCP On/Off 

To start click on the Advanced Setup 
button from your MKII’s homepage.

This page in SONARC allows you to make advanced changes 
to the your amplifiers settings and configuration. 

The Advanced Setup automatically starts out on the General 
Settings tab. This tab is used to set up your MKII with a 
network connection, triggering and other basic information.

Input Settings / Source Select

Input Source

Input Name

This is a user entered field with a maximum of 15 characters. 
Use these fields to describe the type of input connected.

This pull down menu allows you to select which Input you 
would like to assign to the channel.

DHCP ON/OFF is the first option in IP SETUP. All Sonance DSP 
series amplifiers ship with DHCP (Dynamic Host Connection 
Protocol) ON. In most installations DHCP should be left ON
except when you are using a control system for IP control. 
If you are controlling the DSP series amplifier using IP, then 
we suggest you turn DHCP OFF and use a static IP address.

Содержание DSP 8-130 MKII SONAMP

Страница 1: ...DSP 8 130 MKII SONAMP MULTI CHANNEL POWER AMPLIFIER WITH INSTRUCTION MANUAL 06 14 17...

Страница 2: ...and Volume Level Controls 6 Protection Circuitry and LEDs 6 Rack Ear Installation and Shelf Mounting 6 Software V2 7 Network Connection Instructions 7 Homepage 7 Basic Setup Page 7 Advanced Setup Pag...

Страница 3: ...e amplifier use canned air or wipe the amplifier with a soft cloth Do not use solvents as they may damage the amplifier 12 Non use periods Unplug the amplifier s power cord from the outlet when the am...

Страница 4: ...e interventions av rera n cessaire si l appareil a t endommag pour quelque raison que ce soit et par exemple si le c ble d alimentation secteur ou sa prise sont endommag s si du liquide a p n tr l int...

Страница 5: ...mp DSP 8 130 MKII box should contain 1 Quickstart guide 1 Sonamp DSP 8 130 MKII amplifier 1 IEC power cord 4 Feet 2 Rack ears Unpacking Save the carton and polystyrene inserts for future safe transpor...

Страница 6: ...g channels use the two outside connections on each connector The positive wire from the speaker should be on the left side connection and the negative connection should be on the right side Auto On Vo...

Страница 7: ...CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR S N T5AL 250VAC 2 100 AC 100 120V 60Hz CAUTION REPLACE FUSE ONLY WITH SAME TYPE AND RATING ATTENTION REMPLACER U...

Страница 8: ...r extremely low impedance the affected channel outputs automatically mute The output of the effected channel will remain muted until the fault has been corrected Only the effected channels output will...

Страница 9: ...he IP address of the Sonance DSP amplifier to configure SONARC Legend Toggle Pull down Menu Free Type Field Single Action Menu SONARC Homepage Setup Options Your SONARC Homepage will have two options...

Страница 10: ...T AND RIGHT CHANNELS ARE LINKED OUTPUT VOLUME IS LINKED TO TURN ON VOLUME IN BASIC SETUP ADVANCED SETUP PAGE GENERAL SETTINGS TAB Advanced Setup IP SETUP DHCP On Off To start click on the Advanced Set...

Страница 11: ...ep Mode options Each channel has an independent Sleep Mode setting The Sleep Mode is triggered by an audio sensing circuit on each channel of the amplifier Voltage Green In the Voltage Green Auto On m...

Страница 12: ...ments of 5dB This is a user entered field with a maximum of 15 characters Use these fields to describe the location of the speakers Allows each channel to be set for Stereo or Mono operation When Mono...

Страница 13: ...RC software includes a built in pink noise generator The pink noise signal can be used in conjunction with a real time analyzer to measure speakers You have the option of pink noise or test signals fe...

Страница 14: ...se Import Single Preset Copy Preset 1 Import speaker preset to a location on your computer This can be accomplished by saving a DSP preset downloaded from Sonance website 2 Select the location you wou...

Страница 15: ...k of damage to the loudspeakers Crossover LP Xover HP Xover Frequency Filter Type Limiter This setting turns the high and low pass crossovers ON and OFF In this field you can enter any frequency betwe...

Страница 16: ...riven 4 ohms sinewave 1 8 power 226 Watts all channels driven idle 35 Watts Sleep Mode 1 1 Watts Voltage or Audio Green 0 45 Watts Power Consumption 220V AC 8 ohms sinewave full power 1097 Watts all c...

Страница 17: ...eset Steps Step 1 Turn amplifier off Step 2 With light pressure adjust 1L Volume Control full counter clockwise Step 3 With light pressure adjust 1R Volume Control full clockwise Step 4 Power on ampli...

Страница 18: ...LTAGE NONE 6 8 seconds Always On AUTO ON SETTING SLEEP MODE OPTIONS TIME TO MUSIC ETHERNET VOLTAGE GREEN NONE 6 8 seconds Turn Off after 15 MIN without voltage AUTO ON SETTING SLEEP MODE OPTIONS TIME...

Страница 19: ...ALL NOT BE LIABLE FOR CONSEQUENTIAL INCIDENTAL ECONOMIC PROPERTY BODILY INJURY OR PERSONAL INJURY DAMAGES ARISING FROM THE PRODUCT ANY BREACH OF THIS WARRANTY OR OTHERWISE This warranty statement give...

Отзывы: