• Install smoke alarms in circulation areas at a distance no greater than 7.5 m from the farthest
wall, no greater than 7.5 m from a door to any room in which a fire might start and no greater
than 7.5 m from the next smoke alarm.
• Install heat alarms on the ceiling, ideally in the centre of the room.
• Install sufficient alarms to compensate for closed doors and obstacles.
• Install your Thermistek heat alarm at a distance no greater than 5.3 m from the farthest wall, no
greater than 5.3 m from a door to any room in which a fire might start and no greater than 5.3 m
from the next heat or smoke alarm.
✓
POSITIONING
Locations of alarms must be compliant with either BS 5839: Part 6 or relevant Building Regulations if
in any doubt. This alarm is not intended for any non-residential, commercial or industrial application,
nor for any other purpose other than described in the above. For the best protection, heat alarms
should always be installed as part of a complete fire protection system that includes smoke alarms.
Smoke alarms for limited protection