STRUCTURE (Figure 1)
1. glass front panel
2. heater
3. cold air inlets
4. warm air outlet grill
5. main switch
6. ON/OFF button
7. heating stage selector buttons
8. power cable
9. wall-mount console
10. lift-off prevention plate
11. screws and dowels for mounting
Remote control buttons:
12. ON / OFF switch button
13. DATE/TIME (date / time button)
14. ▲, ▼, +, -, OK (multi-selector)
15. IC (automatic heating stage ON / OFF)
16. 1000 W (heating stage selector)
17. 2000 W (heating stage selector)
18. DIMMER (flame effect dimmer)
19. TIMER ON/OFF (timer function ON / OFF)
20. C (delete button)
21. TIMER SET (setting the timer function)
Display:
22. ready status indicator
23. measured temperature / set temperature / program number
24. switch off timing
25. switch on timing
26. time
27. automatic mode
28. flame effect brightness
29. heating stage indicator
30. cursor to select days
31. the days of the week in English
32. active timer
OPERATION
The appliance can be operated using the push-buttons located on the top
or using the remote control.
The unit may emit a slight odor when turned on initially, which is not a
malfunction. It is harmless and evaporates quickly.
Set the main switch (5) to the I (ON) position, then it emits a short beep.
The appliance can be switched on or off using the I/O push-button on top
of the unit.
By being switched on, the flame effect begin to operate only, without any
heating function. Holding the I/O button pressed will toggle among five
brightness settings for the flame effect. The built-in fan heater can be
activated in two stages, 1000 W and 2000 W by using the push-buttons.
The appliance switches on and off depending on the set thermostat
temperature. Pressing the same buttons again will switch off the corres
-
ponding heating stage. The appliance can be switched off anytime using
the I/O push-button.
The ON / OFF button (12) on the remote control functions in the same way
as the I/O button on the appliance. The 1000 W and 2000 W buttons (16
and 17) on the remote can be used to switch on or off the corresponding
heating stages. The currently selected stage can be checked on the
appliance. The DIMMER (18) button can be used to adjust the brightness
of the flame effect in 5 increments.
To set the date and the time, turn on the unit with a remote control ON /
OFF button (12), then press the DATE / TIME button (13). First select the
day, by pressing the „▲”, or „▼” symbols of the multi-selector (14) on
the remote. Press the DATE / TIME button again (13), then set the clock
using the selector dial „+” and „-” buttons. Press the DATE / TIME button
again (13), then set the minute using the selector dial „+” and „-”buttons.
Press the multi-selector (13) to store the set time by pressing the „OK”
symbol.
5. Remove the protective foam padding from the product
and put them back into the carton, in their original location.
Place the appliance on the carton laid onto the floor with
the glass panel facing upwards.
6. Remove the glass panel from the heater by sliding the
glass panel toward the switches. Place the glass panel in a
safe location, away from where the appliance is being as
-
sembled. Do not remove protective film from the glass yet.
7. According to Figure 3, fasten the wall mount (9) horizon
-
tally to the wall at the desired location using the included
screws and dowels. The recommended 600 mm installation
height is not mandatory, however, the minimum height of
300 mm above the floor must be observed. The wall mount
should be flush with the wall. Please take into account the
wall’s bearing capacity.
8. Using the 2 included small screws attach the lift-off
prevention plate (10) onto the bottom of the heater so that
the plate is flush with the wall surface.
9. Hang the heater onto the wall mount.
10. Mark the screw holes of the lift-off prevention plate on
the wall.
11. Remove the heater from the wall then drill holes of
appropriate size to accommodate the dowels into the wall.
Insert the dowels into the holes.
12. Hang the heater back onto the wall mount then fasten
the lift-off prevention plate using the screws.
13. Make sure the device is stably placed on the wall.
14. Hang the glass panel onto the heater at the 2 fixing
points on both sides.
15. Verify that the unit’s mains switch is in the OFF “0”
position.
16. Insert 2 pcs AAA size (1,5 V) alkaline batteries into the
remote controller. Insert the battery considering the polarity.
17. Plug the unit’s standard grounded AC power cable into
a grounded wall outlet. Now the unit is ready for operation.
Do not cover!
Covering the unit can cause overhe
-
ating, fire or electric shock!
Caution: Risk of electric shock!
Do not attempt to disassemble or modify the unit or
its accessories. In case any part is damaged, imme
-
diately power off the unit and seek the assistance of
a specialist.
In the event that the power cable should beco
-
me damaged, it should only be replaced by the
manufacturer, its service facility or similarly qualified
personnel.
FEATURES
● electric wall-mounted decorative fireplace with built-in fan heater for
heating the atmosphere of indoor premises ● attractive flame effects ●
tempered glass front panel ● energy saving LED light source ● adjustable
brightness ● switchable output stages (1000 W / 2000 W) ● electronic
thermostat ● weekly program ● adaptive ON / OFF control ● blow out
point on the top ● overheating protection ● remote control included