background image

Page 36 

Transcend Sleep Apnea Therapy User Manual 

 

 

Appendix: Specifications 

This section presents the following topics: 

 

Transcend 

  

 

AC power supply - PSA2  

 

Mobile power adaptor (optional) - MPA1  

 

Batteries  

 

Transcend performance  

 

Manufacturer’s declaration  

Transcend  

Transcend  weight: 

Less than 1.0 lbs (454 gm) 

Transcend  dimensions: 

6.1 in x 3.5 in x 2.8 in (15.4 cm x 8.9 cm x 7.0 cm) 

Air outlet connector port dimensions: 

19-mm diameter proprietary connector 

Universal Adaptor port dimensions: 

22-mm diameter connector 

AC power supply - PSA2 

AC supply input: 

100-240 VAC, 50-60Hz 

AC supply output: 

19VDC, 2.6 Amp 

Mobile power adaptor (optional) - MPA1 

Mobile power adaptor input: 

13.5 VDC nominal. 12 to 15.5 VDC, 7.0 Amp 

Mobile power adaptor output: 

19.2 DVC, 3.91 Amp 

Batteries (optional) 

Transcend P

8

  Battery: 

14.4 VDC, 5,200 mAH  

Transcend P

4

 t Battery: 

14.4 VDC, 2,600 mAH  

Содержание Transcend Sleep Apnea Therapy

Страница 1: ...Sleep Apnea Therapy System User Manual...

Страница 2: ...International Inc all rights reserved Copyright Copyright 2013 Somnetics International Inc all rights reserved Contact Somnetics International Inc Corporate headquarters Somnetics International Inc Em...

Страница 3: ...ed to be duplex printed printed on both sides of each sheet If not printed in this manner you will find blank pages in your printout Note For purposes of this manual some software screen images may di...

Страница 4: ...nscend P4 or P8 Battery 19 Using the Transcend P4 or P8 Battery with AC line power 19 Using the Transcend P4 or P8 Battery with the Transcend Mobile Power Adaptor 20 Explanation of the optional Transc...

Страница 5: ...arts 35 Accessories 35 Replacement parts 35 Appendix Specifications 37 Transcend 37 AC power supply PSA2 37 Mobile power adaptor optional MPA1 37 Batteries optional P4 and P8 Battery 37 Transcend perf...

Страница 6: ......

Страница 7: ...d is contraindicated in patients with the following conditions Bullous lung disease Pathologically low blood pressure Pneumothorax or pneumomediastinum Pneumocephalus has been reported in some users u...

Страница 8: ...commended accessories Use of accessories not recommended may result in increased electromagnetic emissions or decreased electromagnetic immunity of the PAP system and may be potentially unsafe The Tra...

Страница 9: ...Transcend and contact your physician if respiratory or skin irritations occur Do not introduce objects into the Transcend air inlet or air outlet Inspect the power cord for signs of wear or damage be...

Страница 10: ...uring of medical product Upper and lower temperature limits Separate collection for electrical and electronic equipment per EC Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE Consu...

Страница 11: ...uring shipment Report any missing or damaged items to the home healthcare provider that provided the Transcend System to you Transcend CPAP Standard 6 foot hose Note not compatible with optional H6B o...

Страница 12: ...seal mask cushion for use with H6B or H9M Waterless Humidification Systems Transcend Mobile Power Adaptor Transcend P4 Battery Transcend P8 Battery Battery pouch and chest or arm strap system Transce...

Страница 13: ...very to the interface An external power source connects to the Transcend to supply power to the device Control panel The Transcend control panel has two pushbuttons used to activate the blower and the...

Страница 14: ...ower An optional mobile power adaptor connects to a DC power outlet such as that found in an automobile truck RV boat or similar vehicle Optional Transcend battery packs are also available to power th...

Страница 15: ...py operation ambient air is drawn into the Transcend through an Filter Media The Filter Media should be cleaned at least weekly according to the instructions provided in this User Manual and replaced...

Страница 16: ...attaches to a mating fitting on the interface Assembling the Transcend System Follow these steps to assemble the Transcend System 1 Attach the Universal Hose Adaptor to the 6 foot air supply tube Fig...

Страница 17: ...r Manual Powering the Transcend There are three choices for powering your Transcend device Using the Multi plug Universal Power Supply PSA2 Using the optional Transcend P4 or P8 Battery Using the opti...

Страница 18: ...ply and gently pushing the blade into the slot Turn the blade clockwise until it clicks into place You should hear an audible click 4 Insert the barrel connector of power supply into power jack on the...

Страница 19: ...harge Note Use the battery in line with the AC power supply when possible Connecting the battery in line with the AC power supply allows the battery to charge during therapy and provides backup power...

Страница 20: ...es that power is being supplied to the Transcend and that it has successfully entered Standby Mode Explanation of the optional Transcend P4 and P8 Battery LED lights Red LED light A steady red light s...

Страница 21: ...he initial charge Note To maintain maximum battery performance Somnetics recommends using the Battery in line with the AC Power Supply or Mobile Power Adaptor during therapy even if the battery is ful...

Страница 22: ...o secure Insert the buckle through the loop of the battery pouch with the Velcro facing towards the battery pouch With the pouch loop facing outward wrap the strap around the chest or arm and thread t...

Страница 23: ...Insert the barrel connector of the MPA1 output cable to the power jack of the Transcend 3 Insert the plug connector into the mobile power receptacle e g cigarette lighter outlet 4 The Transcend power...

Страница 24: ...u press the power button The device will repeat the power up LED flash sequence prior to the blower restarting Standard user modes Normal operation consists of four modes Off When the device is not co...

Страница 25: ...was not set for you by a clinician this feature will not be available to you To accelerate the rate of the pressure increase during Ramp hold the Ramp button down until the device reaches a comfortabl...

Страница 26: ...ch therapy session it is recommended the user initiates the Drying Mode To initiate Drying Mode depress the Ramp button and press the Power button simultaneously When in Drying Mode the blower runs at...

Страница 27: ...a new Filter in the channel on the base of the Transcend device 3 Reconnect the Filter Frame to the device by placing the front clip into place first Once the front clip is in place snap the back cli...

Страница 28: ...cleaning and disconnect the device from power cords 2 Mix a solution of 5 mild liquid detergent in distilled water 1 6 fl oz liquid detergent per quart of distilled water Mild detergent should contai...

Страница 29: ...to remove residual cleaning solution 4 Wring excess water from the cloth then wipe the accessory to remove any cleaning solution remaining on its surface 5 Dry surfaces by wiping with a dry lint free...

Страница 30: ...e Clean the foam Filter Media and Filter Frame at least once per week Follow these steps to clean 1 Begin by removing the Filter Media and Filter Frame from the device see Replacing the Filter Media f...

Страница 31: ...lter Media to air dry at room temperature for approximately 30 60 minutes before reassembly Drying time will depend on ambient conditions 13 Reconnect the Filter Media and filter frame to the Transcen...

Страница 32: ...part of the manufacturing process thus this error should only occur then Off Flashes 7 times Pressure sensor out of range While in standby the pressure sensor read a value outside its expected range...

Страница 33: ...n indication that filters and the mask should be inspected for cleanliness and proper fit Filter Media change reminder Every six months the green LED flashes as a reminder that the Filter Media should...

Страница 34: ...ed by a wall switch No airflow from the Transcend Device motor failure or electronics failure Contact the homecare provider s technical service department Yellow fault LED flashes general fault warnin...

Страница 35: ...ouch P4 Battery 503028 Transcend P4 Battery 503026 Base Station 503033 Mobile Power Adapter MPA1 503029 LCD Programming Base Station 503055 Battery Chest Strap 503024 Portable Solar Charger 503056 Rep...

Страница 36: ...in x 3 5 in x 2 8 in 15 4 cm x 8 9 cm x 7 0 cm Air outlet connector port dimensions 19 mm diameter proprietary connector Universal Adaptor port dimensions 22 mm diameter connector AC power supply PSA...

Страница 37: ...m system shutdown pressure 30 cm H2O Ramp time duration 0 45 min 25 time variance Operating temperature range 41 to 95 F 5 to 35 C Storage transport temperature range 4 to 140 F 20 to 60 C Operating h...

Страница 38: ...directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC...

Страница 39: ...ered from the battery Note UT is the A C line voltage before application of the test level Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be a...

Страница 40: ...ics Interface shell seal weight 0 14 lbs 62 g Seal dead space Less than 301 cc 9 Transcend hose dimensions 16 mm diameter 20 cm long 6 Transcend hose dimensions 16 mm diameter 1 9 m long 6 Standard ho...

Страница 41: ...e flow at the patient connection port l min 71 91 75 45 74 29 73 24 71 49 HME moisture loss Test condition Tidal volume ml Breath rate 1 min Moisture loss mg L 1000 10 18 5 750 12 18 6 500 15 15 6 250...

Страница 42: ...which may be claimed to arise from any sale or use of its products Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may...

Страница 43: ...tional Inc 33 5th Avenue NW Suite 500 New Brighton Minnesota 55112 USA http www mytranscend com Phone 651 621 1800 Toll free 877 621 9626 Fax 651 204 0064 Transcend Sleep Apnea Therapy System User Man...

Отзывы: