8
© 2010 Somfy SAS. All rights reserved. 01/2012
EN
1 General
This setting cable is used for adjustment and testing of shutters, equipped with Somfy 230 V AC motors.
It is suitable for radio motors and WT motors (cable).
Ref.: 9 015 971
2 Control and display elements
The push buttons
▲
and
▲▼
must
not
be activated with the following motors:
LS, LT, LT PA, Orienta motors, J41TN/2TN/HTM (damage can be caused to!).
Shines yellow, if setting cable is
connected to power supply.
Push button for RTS/io motors
only; connects RTS/io motor with
power supply (
▲
terminal).
Push button for UP and DOWN drive
of the motor; no function for RTS/io.
Push button for electronic motors
(WT) only. Access and exit of
programming mode. Both running
directions are provided with power
supply. Please follow the manual of
the WT motor. Push button with no
function on radio motors (RTS/io).
Shines red, if RTS/io motor is con-
nected to power supply, push button
▲
activated.
Supply voltage:
230 V AC 50 Hz
Environmental conditions:
Dry rooms
Output voltage:
230 V AC 50 Hz
Conformity:
EN 61439-1
Current output:
max. 4 A
Measurements (W x H x D): 7 x 3 x 14 cm
Protection class:
II,
looped through PE connection
Weight:
567 g (incl. cable)
Degree of protection:
IP 40
Pollution degree:
1
Operating temperature: - 10 ° C bis + 50 ° C
Environment:
B
1.1
General safety precautions
Prior to use the setting cable has to be checked for damage!
Faulty setting cables must not be used.
Neutral wire can carry voltgage if the mains plug will be connected.
Remove the mains plug before conneting or disconnecting the motor to the
clamp terminal
Please follow the manual of the respective motor!
Only 1 motor should be connected to the setting cable at one time
(exception: electronic WT motors).