PAN15-1 

Smart energy plug in switch

 

     

 

 

 

 

 

 

 

 

This  plug-in  ON/OFF  switch  PAN15 is  a  security  enabled  wireless  switch, based  on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  connected  load  is  possible  with  other  manufacturer’s  wireless  Controller.  Each 
switch  is  designed  to  act  as  a  repeater.  Repeaters  will  re-transmit  the  RF  signal  to 
ensure  that  the  signal  is  received  by  its  intended  destination  by  routing  the  signal 
around  obstacles  and  radio  dead  spots.  Because  PAN15  supports  Security 
Command Class, it can learn with Secured controller. Its functionality and supported 
command classes is identical when included as a secure and non-secure device. 
 
This  plug-in  ON/OFF  switch  is  able  to  detect  instance  wattage  (1560W/UL/TW/JP) 
and  overload  current  (14.5A)  of  connected  lights  or  appliances. 

When  detecting 

overload  state,  the  Switch  will  be  disabled  and  its  On/Off  button  will  be  lockout  of 
which LED will flash quickly.  However, unplug and re-connect the switch will reset its 
overload condition to normal status. 
 

Adding to Z-Wave

TM

 Network

 

 
In  the  front  casing,  there  is  an  On/Off  button  with  LED  indicator  which  is  used  to 

toggle switch on and off or carry out inclusion, exclusion, reset or association. When 
first  power  is  applied,  its  LED  flashes  on  and  off  alternately  and  repeatedly  at  0.5 
second  intervals.  It  implies  that  it  has  not  been  assigned  a  node  ID  and  start  auto 
inclusion.  
 

Auto Inclusion

 

 
The function of auto inclusion will be executed as long as the switch does not have 
Node ID and just plug the switch into a wall outlet.

 

 
Note:

 Auto inclusion timeout is 2 minute during which the node information of 

explorer frame will be emitted once several seconds. Unlike “inclusion” function as 
shown in the table below, the execution of auto inclusion is free from pressing the 
On/Off button on the Switch. 
 
The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to 

Add/Remove

/associate devices 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

LED 2-second on, 2-second 
off

 

Add

 

1.Put your Z-Wave controller into  

inclusion mode by following the  
instructions provided by the  
controller manufacturer. 

 

 

2. Pressing On/Off button three times 

 within 2 seconds will enter inclusion  

mode.

 

Remove

 

1.Put your Z-Wave controller into  

exclusion mode by following the  
instructions provided by the  
controller manufacturer.

 

 

1.

 

Pressing On/Off button three times 
within 2 seconds will enter exclusion 
mode.

 

Node ID has been excluded.

 

LED 0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Содержание PAN15-1

Страница 1: ...oggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a w...

Страница 2: ...intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not l...

Страница 3: ... send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter M...

Страница 4: ...e 3 256 Meter Value 4 800 35 KW h 2 2 3 Clearing accumulated power consumption Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale ...

Страница 5: ...t its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PAN15 will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 ...

Страница 6: ...otect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN15 is based on 500 series SoC...

Страница 7: ... systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital d...

Страница 8: ...r s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Information Company s Markings Purpose of control Operating electronic appliance control Construction of the control Plug In operating control Type 1 or Type 2 Action Type 1 Operating Time Continuous ...