![Philio PAN15-1 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/philio/pan15-1/pan15-1_manual_1537961003.webp)
3
Binary Switch Get Command:
[Command Class Switch Binary, Switch Binary
Get]
Binary Switch Report Command:
Report OFF:
[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:
[Command Class Switch Binary, Switch Binary Report, Value =
255(0xFF)]
1-2 BASIC_SET / SWITCH_BINARY_SET
Upon receipt of the following commands from a Z-Wave Controller, the load
attached to the Switch will turn on or off.
[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]
: the load
attached to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]
: the load attached to the
Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99,
(255)0xFF]
: the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]
: the
load attached to the Switch turns off.
1.
Z-
Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to associated Z-Wave devices. It supports
one association group with one node support for Grouping 1. For group 1, the Switch
will report its latest status to Z-Wave Controller.
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT,
ALARM_REPORT.
2-1 Auto report to Grouping 1 (Maximum Node 1)
2-1-1 On/Off Event Report
When “on” or “off ” state has been changed, it will send Binary Switch Report to the
node of Grouping 1.
Binary Switch Report
ON:
[Command Class Switch Binary, Switch Binary Report, Value
=255(0xFF)]
OFF:
[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Grouping 1.
Meter Report Command:
[Command Class Meter
,
Meter Report
,
Rate Type
= 0x01
,
Meter Type = 0x01
,
Precision = 1
,
Scale = 0x02
,
Size =
4
,
Meter Value(W)
2-1-3 Overload alarm report
When PAN15 detects the current is more than 14.5A, it will send Alarm Report to
Group 1 node.
After detecting overload state and sending this alarm report, PAN15
will turn off the switch automatically and lockout the On/Off button. The only thing to
do is unplug PAN15 and reduce the load. Then replug PAN15 and it will work again.
The content of Alarm Report
Alarm report command:
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08,
Alarm Level = 0xFF]
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3)
AC load Voltage (V) or (4)
AC load current ( I )
(5)
load power factor (PF) to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command:
[Command Class Meter, Meter Get, Scale =0x02(W)]