background image

 

setting is enable mode.  

3-7 LED indication mode : 

 3-7-1 Show Switch State

When switch is on, LED is on. When switch is off, LED 

is off. The default setting is Show Switch State. 

 3-7-2 Show Night mode

When switch is on, LED is off. When switch is off, LED 

is on. 

3-8 Auto off timer

 

 Whenever PAN15 switches to on, the auto off timer begin to count down. After the 

timer decrease to zero, it will switch to off automatically. However if Auto off timer 

is set as 0, the auto off function will be disabled. The default setting is 0. 

3-9 RF off command mode 

 Whenever

 

a switch off  command, 

BASIC_SET

BINARY_SWITCH_SET

SWITCH_ALL_OFF, is received, it could be 

interpreted as 4 variety of commands.  

3-9-1 Switch Off

It switches to OFF state. The default setting is Switch Off. 

3-9-2 Ignore

The switch off command will be ignored. 

3-9-3 Switch Toggle

It switches to the inverse of current state. 

3-9-4 Switch On

It switches to ON state. 

3-10 Switch status report mode

 

 Whenever the status of switches changes, it will send a Binary Switch report to the 

group1 node. The default setting is 

1 (Enable)

 
4. 

Protection Command Classes

 

PAN15 supports Protection Command Class version 2, it can protect the switch 

against unintentionally control by e.g. a child. And it can also protect the switch from 
being turned off by setting it in “No RF Control” state.  
After being set to “Protection by sequence” state, any intentional pressing of On/Off 

button should be hold longer than 1 second, or the switch state will not change. 

However, the operation of learn function does not change, because learning will not 

be protected.  

 

 

5. 

Firmware update over the air (OTA)

 

PAN15 is based on 500 series SoC and supports Firmware Update Command Class, 

it can receives the updated firmware image sent by controller via the Z-wave RF 

media. It is a helpful and convenient way to improve some function if needed. 

 

6. 

Command Classes

 

The Switch supports Command Classes including… 

* COMMAND_CLASS_ZWAVEPLUS_INFO 

* COMMAND_CLASS_VERSION 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

* COMMAND_CLASS_SECURITY 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY 

* COMMAND_CLASS_ASSOCIATION_V2 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO 

* COMMAND_CLASS_POWERLEVEL 

* COMMAND_CLASS_SWITCH_BINARY 

* COMMAND_CLASS_BASIC 

* COMMAND_CLASS_SWITCH_ALL 

* COMMAND_CLASS_METER_V3 

* COMMAND_CLASS_CONFIGURATION  

* COMMAND_CLASS_ALARM 

* COMMAND_CLASS_PROTECTION 

* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 

 

Troubleshooting

                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working and 
LED off

 

1.  The Switch is not 

plugged into the 
electrical outlet 
properly 

2.

 

The Switch break 
down

 

7. 

Check power connections 

2. Don’t open up the Switch and send it 

for repair.

 

The Switch LED 

1.Check if the load 

1. Set the ON/OFF switch of the load 

Содержание PAN15-1

Страница 1: ...oggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a w...

Страница 2: ...intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not l...

Страница 3: ... send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter M...

Страница 4: ...e 3 256 Meter Value 4 800 35 KW h 2 2 3 Clearing accumulated power consumption Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale ...

Страница 5: ...t its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PAN15 will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 ...

Страница 6: ...otect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN15 is based on 500 series SoC...

Страница 7: ... systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital d...

Страница 8: ...r s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Information Company s Markings Purpose of control Operating electronic appliance control Construction of the control Plug In operating control Type 1 or Type 2 Action Type 1 Operating Time Continuous ...