2.1.4.Installing the drive-tube assembly
CAUTION
The motorised product must not be compressed between the brackets.
1]
If necessary, screw the bracket adapter to the drive head (
f
).
2]
Assemble and fix the drive-tube assembly onto the end bracket (
g
) and onto
the drive bracket (
h
).
1]
2]
f
g
h
CAUTION
Ensure that the drive-tube assembly is secured onto the end bracket. This operation prevents the tube-drive
assembly from coming out of the end bracket attachment.
2.2.Wiring
WARNING
To ensure electrical safety, this Class III drive must be powered by a «SELV» voltage source (Safety Extra Low
Voltage).
PRECAUTION
• Cables routed through a metal wall must be protected and insulated by sleeving or sheathing.
• Secure the cables to prevent any contact with moving parts.
• If the drive is used outdoors and if the power supply cable is of the H05-VVF type, run the cable in a UV-resistant
duct, e.g. trunking.
• The drive cable cannot be removed. If it is damaged, return the drive to the After-Sales department.
CAUTION
• The cable between the drive and the power supply must not exceed 2,5 m (with wire cross-section min. 0.75mm²).
• Leave the drive power supply cable accessible: the product must be easily replaceable.
• Always make a loop in the power supply cable to prevent water from entering the drive.
2.2.1.Wiring with connectors
1]
Wire the 4-pin drive connector (
i
) to the 4-pin
cable Y connector (
j
).
2]
Wire the 2-pin cable Y connector (
k
) to the 2-pin
battery connector (
m
).
3]
Wire the 4-pin cable Y connector (
o
) to the 2-pin
solar panel connector (
p
).
i
j
o
p
k
m
5113030C_Sunea 40 RTS DC.pdf 6