18
Copyright © 2013 Somfy SAS. All rights reserved.
V
4 cm
Connecting the control unit to the power supply
On a 3 x 1.5 mm² type cable, prepare 2 wires of 4 cm (live
and neutral)
1
Connect the live and neutral to terminals 15 and 16 (red
"230 V" label on the electronics)
2
Immobilise the 230 V power supply cable with the cable
clamp provided (19).
Fit a terminal block on the earth wire (yellow/green) and
store it in the control unit.
24V
Live
Live
Neutral
Neutral
Other connections (optional)
l
Cells (see page 25)
l
Orange light (see page 26)
l
Other accessories (see pages 26 to 28)
230V power supply cable
230V power supply cable
Connecting the motors
5
Motor
M1
activates the gate leaf which
opens first and closes last,
and opens for pedestrian access.
With the gate closed, identify the gate
leaf that opens first. M1 activates this
gate leaf.
1
Connect the motors as indicated in the table below:
2
M1 est à gauche
OU
M1 est à droite
Connect the wire of ... to terminal ...
M1
blue
9
brown
10
M2
blue
11
brown
12
Connecting to the mains power supply
6
Ensure that the installation is powered off.
Cable clamp
M1 is to the left
or
M1 is to the right
Содержание SGS 201
Страница 1: ...5073893A SGS 501 EN Operating and installation guide DE Montage und Gebrauchsanleitung ...
Страница 70: ......
Страница 71: ......